Related Experiment Video
Updated: Nov 17, 2025

Manufacture of a Multi-Purpose Low-Cost Animal Bench-Model for Teaching Tracheostomy
Published on: May 18, 2019
Will Protective Innovations Like the "Airway Box" Become Routine Practice After the Pandemic?: An Opinion Survey
Pavithra Ellison1, Benton Nanners1, Gregory Schaefer2
1Anesthesiology, West Virginia University School of Medicine, Morgantown, USA.
Abstract:
Background Tracheal intubation carries an elevated risk of exposure to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) due to the generation of aerosols containing high concentrations of the virus. An airway box was designed to mitigate the exposure of healthcare professionals performing intubations. Aim We evaluated usability and sustainability in the routine practice of the "airway box" as a protective device during high-risk airway procedures. Materials and methods After institutional review board approval, clinicians were educated on using the device through simulation, intranet learning modules, and emailed resources. The airway box was made available in the emergency department, critical care units, perioperative area, and operating rooms. QR codes affixed to the box, emailed, and displayed in common areas provided easy access to complete a REDcap survey (Vanderbilt University Nashville, USA) eliciting providers' experience. Data was collected and analyzed between April 1 and July 31, 2020, on REDcap, and the results were analyzed. Results 687 emergent intubations took place. 232 were performed by anesthesiologists, 315 by emergency department providers, and 140 by critical care specialists. 39 surveys were completed, 29 from intubations in the operating room, three from the critical care units, five from interventional radiology suites, and two perioperatively. Providers found the device to be readily available, with a score of 4.51/5, and the majority of providers, 60%, found the device easy to use, rating it either a 4 or 5 out of 5. Providers acquired a mean Mallampati score of 1.75 and 1.40 mean laryngoscopic grade view. Conclusion Intubation boxes may effectively mitigate high-risk viral exposure during airway procedures. Survey responses show that devices were easy to use and did not significantly affect visualization of the airway. Similar to mask use, enclosure devices in clinical practice could become a vital part of medical protective equipment even after the SARS-CoV-2 pandemic if they are effectively implemented.
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Suctioning the Nasopharyngeal Airway
Equipment Required
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...

