Related Experiment Video
Updated: Nov 17, 2025

The WATCHMAN Left Atrial Appendage Closure Device for Atrial Fibrillation
Published on: February 28, 2012
Difficulty removing dialysis cuff catheter after its adhesion to the right atrium
Tomonari Ogawa1, Megumi Inamura1, Yuichiro Kawai1
1Department of Nephrology and Blood Purification, Saitama Medical Center, Saitama Medical University, Saitama, Japan.
Abstract:
We describe the case of an elderly Japanese female who had experienced diabetic nephropathy since the year 20xx and had been undergoing dialysis treatment while receiving vascular access interventional therapy (VAIVT) for arteriovenous fistula (AVF) occlusion. The patient visited the clinic/hospital in 20xx+10 with the AVF occlusion; emergency VAIVT was performed but blood flow could not be resumed. The patient was not admitted and was treated as an outpatient, and thus a cuff catheter (Split stream catheter: SST28 cm, Medcomp) was inserted. An infection developed and was successfully treated with antibiotics. The dialysis treatment continued without issue. One year after the cuff catheter's insertion, the patient was admitted due difficulty breathing. Despite continued dialysis treatment with the catheter, the patient died 15 days post-admission. The removal of the catheter proved to be difficult. An autopsy was approved, and the area around the catheter was examined. The adhesion of the catheter to the right atrium was observed, but no infection was detected in the bloodstream. This case illustrates that dialysis with the use of a cuff catheter can be effective.
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
Hemodialysis I: Introduction
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization IV: Nursing Management
Hemodialysis II: Procedure and Complications
Cardiac Catheterization III: Left Heart Catheterization