Related Experiment Video
Updated: Nov 17, 2025

Infrared Thermography for the Detection of Changes in Brown Adipose Tissue Activity
Published on: September 28, 2022
[Screening of febrile cows using a small handheld infrared thermography device]
Ulrich Bleul1, Michael Hässig2, Fabienne Kluser1
1Clinic of Reproductive Medicine, Department of Farm Animals, Vetsuisse-Faculty University Zurich.
Objective:
As dairy herds increase in size, close monitoring of health becomes a necessity, but this is expensive and labour-intensive. Early detection of febrile diseases is essential for economical and welfare reasons and to prevent the spread of disease. The goal of this study was therefore to evaluate a mobile, non-invasive technique for measuring the body temperature of cows that precludes the need for restraint of the animals.
Materials And Methods:
An infrared thermographic imaging camera installed on a smart phone was used to measure the surface temperature of cows. In experiment 1, a metal block heated to defined temperatures was used to obtain infrared thermographic measurements (THM). The accuracy of THM made at different distances from the block and at 2 different ambient temperatures was determined. In experiment 2, non-febrile cows underwent infrared thermographic imaging, and the body regions with the highest correlations between thermographic and rectal temperature were identified. In experiment 3, THM were made in febrile and neighbouring non-febrile cows.
Results:
In experiment 1, the thermographic and true temperatures of the block had the strongest relationships at 0.5 and 1.0 m (r = 0.98). The ambient temperature had a significant effect on the THM, which had larger variations and greater deviations from the block temperature at 14.8 °C than at 23.8 °C. In experiment 2, the maximum temperature at the eye (r = 0.37), THM at the muzzle (r = 0.28) and the medial canthus (r = 0.27) showed the strongest relationships with the rectal temperature. After correcting the THM with the mean difference between thermographic and rectal temperatures of the non-febrile cows, sensitivities of 88, 90 and 82 %, respectively, were calculated for THM at the muzzle, eye and medial canthus in febrile cows in experiment 3. The corresponding specificities were 6, 23 and 32 %.
Conclusion And Clinical Relevance:
Based on the low specificities of the infrared THM, the thermographic imaging camera has limited usefulness for the mass screening of dairy cows for febrile conditions. Cattle falsely identified as febrile need to be separated, caught and re-examined, which causes unnecessary stress to the animal and increases labour input.
More Related Videos
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...