Related Experiment Video
Updated: Nov 17, 2025

Determining and Controlling External Power Output During Regular Handrim Wheelchair Propulsion
Published on: February 5, 2020
Reliability and sensitivity of the Notio Konect to quantify coefficient of drag area in elite track cyclists
Mehdi Kordi1,2, Gert Galis3, Teun van Erp4
1Royal Dutch Cycling Federation (KNWU), Arnhem, Netherlands.
Abstract:
Elite level cycling events are performed at speeds in excess of 50 km/h. At these speeds, over 90% of the resistance forces come from aerodynamic resistance (CDA). Recently bicycle-mounted pitot tubes, such as the Notio Konect (NK) have become more commercially available making CDA easier to measure. Its reliability and sensitivity would be useful for riders and coaches to be able to understand what constitutes as a change in CDA. Accordingly, the aim of this study was to establish the intra- and inter-effort reliability and sensitivity of the CDA measures of the NK. Seven elite level track riders were used in this study which was broken into two parts: (1) Reliability and (2) Sensitivity. For both parts of the experiment, riders performed identical efforts, riding at ∼50 km/h for six laps of a 250 m indoor velodrome. For reliability, the riders performed six efforts without any changes in position or resistance. For sensitivity, they performed the efforts with a rod with discs of a known diameters attached at each end to vary the CDA by a known amount. For the reliability assessment, low coefficient of variation of intra - (0.47%) and inter-effort (0.9%) reliability were measured. With regards to sensitivity, the smallest changes in resistance (from 5 - 6 cm, i.e. 1.2% or 0.002 m2) was identified by the NK. The data in this experiment suggests that the NK is a highly reliable in measuring CDA can detect changes up to at least 1.2% in an indoor velodrome using elite level track riders. HighlightsThe Notio Konect showed high levels of inter- and intra-effort reliability.The Notio Konect could detect a change as small as 1.2% in aerodynamic drag.The findings suggest that the Notio Konect is suitable for detecting small changes in aerodynamic drag in a velodrome setting.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
10:28Kinematics and Ground Reaction Force Determination: A Demonstration Quantifying Locomotor Abilities of Young Adult, Middle-aged, and Geriatric Rats
Published on: February 22, 2011
Related Concept Videos
Drag
Correlation of Experimental Data
For example, a spherical particle moving through a viscous fluid experiences drag. Dimensional analysis shows that the drag force depends on the particle's diameter, velocity,...
Coefficient of Correlation
If you suspect a linear relationship between x and y, then r can measure how strong the linear relationship is.
What the VALUE of r tells us:
The value of r is always between –1 and +1: –1 ≤ r ≤ 1.
The size of the correlation r indicates the...
Net Torque Calculations
Turnover Number and Catalytic Efficiency
Chymotrypsin is a pancreatic enzyme that breaks down proteins during digestion....
Factors Affecting Activity Coefficient
The activity coefficient value for an ion is close to one when the solution has almost zero ionic strength, i.e., when the solution shows close to ideal behavior. As the ionic strength of the solution increases from 0 to 0.1 mol/L, a...