Cessation classification likelihood increases with higher expired-air carbon monoxide cutoffs: a meta-analysis
Joshua L Karelitz1, Erin A McClure2, Caitlin Wolford-Clevenger3
1Division of Cancer Control and Population Sciences, UPMC Hillman Cancer Center, University of Pittsburgh, 5150 Centre Ave, Suite 4C, Pittsburgh, PA, 15232, USA; Department of Epidemiology, Graduate School of Public Health, University of Pittsburgh, 5150 Centre Ave, Suite 4C, Pittsburgh, PA, 15232, USA.
Background:
Expired-air carbon monoxide (CO) is commonly used to biochemically verify smoking status. The CO cutoff and CO monitor brand may affect the probability of classifying smokers as abstinent, thus influencing conclusions about the efficacy of cessation trials. No systematic reviews have tested this hypothesis. Therefore, we performed a meta-analysis examining whether the likelihood of smoking cessation classification varied due to CO cutoff and monitor brand.
Methods:
Eligible studies (k = 122) longitudinally assessed CO-verified cessation in adult smokers in randomized trials. Primary meta-regressions separately assessed differences in quit classification likelihood due to continuous and categorical CO cutoffs (Low, 3-4 parts per million [ppm]; [SRNT] Recommended, 5-6 ppm; Moderate, 7-8 ppm; and High, 9-10 ppm); exploratory analyses compared likelihood outcomes between monitor brands: Bedfont and Vitalograph.
Results:
The likelihood of quit classification increased 18% with each 1 ppm increase above the lowest cutoff (3 ppm). Odds of classification as quit significantly increased between each cutoff category and High: 261% increase from Low; 162% increase from Recommended; and 150% increase from Moderate. There were no differences in cessation classification between monitor brands.
Conclusions:
As expected, higher CO cutoffs were associated with greater likelihood of cessation classification. The lack of CO monitor brand differences may have been due to model-level variance not able to be followed up in the present dataset. Researchers are advised to report outcomes using a range of cutoffs-including the recommended range (5-6 ppm)-and the CO monitor brand/model used. Using higher CO cutoffs significantly increases likelihood of quit classification, possibly artificially elevating treatment strategies.
More Related Videos
06:22Machine Learning-Based Cough Tone Classification: Diagnostic Exploration of Chronic Obstructive Pulmonary Disease and Respiratory Tract Infections
Published on: September 19, 2025
10:44Comparing the Effects of Electronic Cigarette Vapor and Cigarette Smoke in a Novel In Vivo Exposure System
Published on: May 24, 2017
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Chronic Obstructive Pulmonary Disease-I: Introduction
COPD: Management Using Bronchodilators and Corticosteroids
Acute Respiratory Failure-III