Related Experiment Video
Updated: Nov 17, 2025

Adjustable Stiffness, External Fixator for the Rat Femur Osteotomy and Segmental Bone Defect Models
Published on: October 9, 2014
A novel low-profile external skeletal fixator for type IIIB open tibial fractures: A biomechanical and clinical pilot
Yih-Wen Tarng1,2, Kai-Cheng Lin1, Kun-Jhih Lin3,4
1Department of Orthopaedics, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan, ROC.
Background:
Although external fixator is standard for managing staged treatment of open tibial fracture, the main disadvantage of this device is too bulky to be tolerated by most patients for longtime use. The purposes of this pilot study were to compare the biomechanical properties of a novel low-profile external fixator (LP-ESF) with a traditional ESF and also to evaluate its performance in patients with Gustilo type IIIb tibial open fractures.
Methods:
A prospective clinical pilot study started from January 2015 to December 2017, and 18 patients with Gustilo type IIIb open tibial fractures underwent the fixation with a novel LP-ESF system. The biomechanical properties of the LP-ESF were compared with the Synthes External Fixation System according to the standard ASTM F1541-02. These patients were divided into two groups according to the size of bony defect. The postoperative clinical outcomes were subsequently collected.
Results:
The biomechanical properties of the LP-ESF were comparable with those of Synthes External Fixation System and had an improved the axial/torsional stiffness and ultimate strength. In the clinical study, all patients with LP-ESF had fracture union. The duration of application of LP-ESF was 3.5 to 18 months until fracture union. In 10 of 18 patients, their fractures were immobilized with the LP-ESF until bone union, and no pin tract infection and no chronic osteomyelitis were recorded. The 36-Item Short Form Health Survey life quality and health survey were good to excellent in these patients. Notably, the LP-ESF allowed a patient with severe bone and soft-tissue defects to preserve the leg and joints function.
Conclusion:
In this study, we found that the novel LP-ESFs had improved clinical outcomes. The long-term LP-ESF application seems to be tolerable in our patients. This novel approach permits better controls in deep infection and faster healing of fractures, and thus may provide a viable alternative treatment for Gustilo type IIIb open tibial fractures.
More Related Videos
05:34A Mini-Invasive Internal Fixation Technique for Studying Immobilization-Induced Knee Flexion Contracture in Rats
Published on: May 20, 2019
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018