Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

High-Performance Liquid Chromatography: Introduction01:11

High-Performance Liquid Chromatography: Introduction

2.9K
High-performance liquid chromatography(HPLC), formerly referred to as High-pressure liquid chromatography, is a powerful technique used to separate, identify, and quantify components in complex mixtures. The term "high pressure" refers to using high pressure to push the liquid mobile phase through the tightly packed columns.
In HPLC, two phases play a critical role in the separation process:
2.9K
Chromatographic Methods: Terminology01:18

Chromatographic Methods: Terminology

3.0K
Chromatography is an analytical technique widely used in fields such as chemistry, biology, environmental science, and pharmaceuticals to separate the components of a mixture and identify substances between them. The process of chromatography is based on the interactions between two distinct phases: the stationary phase and the mobile phase. The stationary phase is fixed in place by a supporting material, while the mobile phase moves over it, carrying the solutes. As the mobile phase travels,...
3.0K
High-Performance Liquid Chromatography: Elution Process01:05

High-Performance Liquid Chromatography: Elution Process

1.1K
In High-Performance Liquid Chromatography (HPLC), the elution process is critical to the separation of analytes and the quality of chromatographic results. Elution describes how compounds move through the column and separate based on their interactions with the mobile and stationary phases. This process determines the resolution, peak shape, and retention times in the chromatogram, which are essential for identifying and quantifying components in complex mixtures. Understanding the elution...
1.1K
High-Performance Liquid Chromatography: Instrumentation00:57

High-Performance Liquid Chromatography: Instrumentation

2.5K
High-performance liquid chromatography, or HPLC, is an analytical technique that separates liquid samples under high pressures. An HPLC instrument consists of glass bottles for storing solvents called mobile phase reservoirs. HPLC-grade solvents are used to maintain high purity, and the dissolved gases are removed using a degasser, such as a vacuum pumping system or sparging with helium. The solvents are then pumped into the analytical column using a screw-driven syringe or reciprocating pumps.
2.5K
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

1.2K
The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte...
1.2K
Chromatographic Resolution01:15

Chromatographic Resolution

1.5K
In chromatography, a solute moves through a chromatographic column and tends to spread, forming a Gaussian-shaped band. The longer the solute spends in the column, the broader the band becomes. The broadening can lead to overlaps within the column, affecting separation effectiveness.
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
1.5K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Continuous Hydrogen Sulfide Monitor Based on Positive Fluorescence Green Chemistry. Application to Geothermal Powerplant Environmental Impact Assessment.

ACS omega·2026
Same author

Functionalization of High-Density Polyethylene Capillaries for Open Tubular Ion Chromatography.

Journal of separation science·2024
Same author

Consumption of fruits, vegetables and salt in the context of control of type 2 diabetes and hypertension in Kerala, India.

Journal of family medicine and primary care·2021
Same author

Automated Programmable Generation of Broad pH Range Volatile Ionic Eluents for Liquid Chromatography.

Analytical chemistry·2021
Same author

<i>In situ</i> Generated Ru(0)-HRO@Na-β From Hydrous Ruthenium Oxide (HRO)/Na-β: An Energy-Efficient Catalyst for Selective Hydrogenation of Sugars.

Frontiers in chemistry·2020
Same author

Moldable Strong Cation Exchange Polymer and Microchannel Fabrication.

Analytical chemistry·2020

Related Experiment Video

Updated: Nov 17, 2025

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
10:14

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography

Published on: September 2, 2020

5.2K

Shape-Based Peak Identity Confirmation in Liquid Chromatography.

Akinde F Kadjo1, Purnendu K Dasgupta2, Kannan Srinivasan1

  • 1Thermo Fisher Scientific, 1228 Titan Way, Building 1, Sunnyvale, California 94085, United States.

Analytical Chemistry
|February 18, 2021
PubMed
Summary

Chromatographic peak identification can be unreliable using only retention times. A new sameness threshold (ST) method confirms analyte identity by comparing peak shapes, improving accuracy in chromatography.

More Related Videos

Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
14:42

Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems

Published on: September 23, 2021

5.4K
Highly Sensitive and Quantitative Detection of Proteins and Their Isoforms by Capillary Isoelectric Focusing Method
07:58

Highly Sensitive and Quantitative Detection of Proteins and Their Isoforms by Capillary Isoelectric Focusing Method

Published on: September 19, 2018

6.9K

Related Experiment Videos

Last Updated: Nov 17, 2025

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
10:14

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography

Published on: September 2, 2020

5.2K
Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
14:42

Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems

Published on: September 23, 2021

5.4K
Highly Sensitive and Quantitative Detection of Proteins and Their Isoforms by Capillary Isoelectric Focusing Method
07:58

Highly Sensitive and Quantitative Detection of Proteins and Their Isoforms by Capillary Isoelectric Focusing Method

Published on: September 19, 2018

6.9K

Area of Science:

  • Analytical Chemistry
  • Chromatographic Science

Background:

  • Chromatography separates analytes, with retention time often used for identification.
  • Reliance on retention time alone is problematic due to variability caused by factors like concentration and column aging.
  • Current identification methods struggle with shifting retention times, complicating analysis.

Purpose of the Study:

  • To introduce a novel method for chromatographic analyte identification.
  • To improve the reliability of analyte identification beyond traditional retention time comparisons.
  • To develop a robust system for confirming peak identity in chromatographic data.

Main Methods:

  • Proposed a sameness threshold (ST) for identification confirmation based on chromatographic peak shape.
  • Developed shape-based identification by comparing unknown peaks against a library of standard peak shapes.
  • Utilized metrics like the coefficient of determination (r²) or an index of width mismatch for shape comparison.

Main Results:

  • Demonstrated the effectiveness of shape-based identification for confirming or refuting analyte identity.
  • Showed that the sameness threshold method can accurately identify analytes even when retention times vary.
  • Found that in most cases, only one standard in the library matched the shape of the unknown peak.

Conclusions:

  • Shape-based analysis using a sameness threshold offers a more reliable method for chromatographic analyte identification.
  • This approach mitigates issues associated with shifting retention times, enhancing analytical accuracy.
  • The proposed method provides a robust alternative for confirming analyte identity in complex mixtures.