Related Experiment Video
Updated: Nov 17, 2025

Transradial Access Chemoembolization for Hepatocellular Carcinoma Patients
Published on: September 20, 2020
TIger II vs JUdkins Catheters for Transradial Coronary Angiography (TIJUCA Study): A Randomized Controlled Trial of
Felipe Maia1, Cleverson Zukowski, Mauricio Oliveira
1Rua Almirante Baltazar, 435 (Research Center of Quinta D'Or Hospital), São Cristóvão, Rio de Janeiro 20941-150, Brazil. felipemaia08@gmail.com.
Background:
In high-expertise transradial (TR) centers, the radiation exposure to patients during coronary angiography (CAG) is equivalent to transfemoral use. However, there is no definitive information during TR-CAG regarding the use of a single, dedicated catheter to impart less radiation exposure to patients.
Objective:
We compare the radiation exposure to patients during right TR-CAG with Tiger II catheter (Terumo Interventional Systems) vs Judkins right (JR) 4.0/Judkins left (JL) 3.5 catheters (Cordis Corporation).
Methods:
This multicenter, randomized, and prospective trial included 180 patients submitted to right TR-CAG, with the primary objective of observing radiation exposure to patients through the measurement of fluoroscopy time, air kerma (AK), and dose-area product (DAP) using Tiger II (group 1) vs JR 4.0 and JL 3.5 Judkins catheters (group 2). Secondary outcomes included contrast volume usage and the need to use additional catheters to complete the procedure (the crossover technique).
Results:
Group 1 demonstrated reduced fluoroscopy time (2.47 ± 1.05 minutes in group 1 vs 2.68 ± 1.26 minutes in group 2; P=.01) and non-significant reduction of AK (540.9 ± 225.3 mGy in group 1 vs 577.9 ± 240.1 mGy in group 2; P=.34) and DAP (3786.7 ± 1731.7 μGy•m² in group 1 vs 4058.0 ± 1735.4 μGy•m² in group 2; P=.12). Contrast volume usage (53.46 ± 10.09 mL in group 1 vs 55.98 ± 10.43 mL in group 2; P=.13) and the need for additional catheters (5.56% in group 1 vs 4.44% in group 2; P>.99) were similar between groups.
Conclusion:
The Tiger II catheter was able to reduce radiation exposure to patients submitted to TR-CAG through a significant reduction in fluoroscopy time.
More Related Videos
06:04Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Cardiac Catheterization I: Pre-Procedure Overview
Imaging Studies VII: Vascular Imaging
Cardiac Catheterization III: Left Heart Catheterization