Related Experiment Video
Updated: Nov 17, 2025

Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging
Published on: May 5, 2011
Point-of-care infrared thermal imaging for differentiating venomous snakebites from non-venomous and dry bites
Paramasivam Sabitha1, Chanaveerappa Bammigatti1, Surendran Deepanjali1
1Department of Medicine, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India.
Background:
Local envenomation following snakebites is accompanied by thermal changes, which could be visualized using infrared imaging. We explored whether infrared thermal imaging could be used to differentiate venomous snakebites from non-venomous and dry bites.
Methods:
We prospectively enrolled adult patients with a history of snakebite in the past 24 hours presenting to the emergency of a teaching hospital in southern India. A standardized clinical evaluation for symptoms and signs of envenomation including 20-minute whole-blood clotting test and prothrombin time was performed to assess envenomation status. Infrared thermal imaging was done at enrolment, 6 hours, and 24 hours later using a smartphone-based device under ambient conditions. Processed infrared thermal images were independently interpreted twice by a reference rater and once by three novice raters.
Findings:
We studied 89 patients; 60 (67%) of them were male. Median (IQR) time from bite to enrolment was 11 (6.5-15) hours; 21 (24%) patients were enrolled within 6 hours of snakebite. In all, 48 patients had local envenomation with/without systemic envenomation, and 35 patients were classified as non-venomous/dry bites. Envenomation status was unclear in six patients. At enrolment, area of increased temperature around the bite site (Hot spot) was evident on infrared thermal imaging in 45 of the 48 patients with envenomation, while hot spot was evident in only 6 of the 35 patients without envenomation. Presence of hot spot on baseline infrared thermal images had a sensitivity of 93.7% (95% CI 82.8% to 98.7%) and a specificity of 82.9% (66.3% to 93.4%) to differentiate envenomed patients from those without envenomation. Interrater agreement for identifying hot spots was more than substantial (Kappa statistic >0.85), and intrarater agreement was almost perfect (Kappa = 0.93). Paradoxical thermal changes were observed in 14 patients.
Conclusions:
Point-of-care infrared thermal imaging could be useful in the early identification of non-venomous and dry snakebites.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...

