Related Experiment Video
Updated: Nov 17, 2025

Installation Method to Enhance Quality Control for Fiber Reinforced Polymer Spike Anchors
Published on: April 10, 2018
The effect of clinically recommended Evolut sizes on anchorage forces after BASILICA
Halit Yaakobovich1, Romina Plitman Mayo2, Uri Zaretsky1
1Department of Biomedical Engineering, Tel Aviv University, Tel Aviv, Israel.
Abstract:
Coronary artery obstruction (CAO), a fatal complication of transcatheter aortic valve replacement (TAVR), is commonly found after Valve-in-Valve implantation inside a degenerated bioprosthetic valve. Leaflet laceration (BASILICA technique) has been proposed to prevent CAO and to potentially reduce the risk of leaflet thrombosis. We have previously demonstrated that this technique can reduce the anchorage forces of the TAVR device, which may lead to future complications. In this short communication, we hypothesize that the anchorage force reduction can be minimized by implanting a TAVR with a larger diameter, if two sizes are clinically recommended. We evaluated this hypothesis by employing finite element models of the deployments of the Evolut 26 and 29 mm inside a 27 mm Mitroflow valve, with and without leaflet lacerations. The results show that a laceration substantially decreases the contact area between the Evolut stent and the Mitroflow valve. The larger Evolut has a larger contact area and stronger anchorage forces. Additionally, the anchorage forces are less sensitive to additional lacerations in the larger Evolut (29 case). The results suggest that a larger self-expending device can ensure stronger anchorage and can lower the risk of possible migration, when TAVR is performed in a lacerated bioprosthesis.
More Related Videos
Related Concept Videos
Design Example: Dimensioning of Concrete Masonry Construction
The site engineer has laid out a plan for the storeroom with external dimensions of twelve feet in length and...
Anchoring Junctions
Design of Columns under a Centric Load
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating...
Tension Response at Adherens Junctions
α-Catenin as a Mechanosensory Protein
The α-catenin of adherens junctions is an allosteric protein with three VH (vinculin...
Impact Strength of Concrete
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...

