Synchrotron X-ray Microdiffraction and Fluorescence Imaging of Mineral and Rock Samples
Published on: June 19, 2018
Monte Carlo study of a convergent X-ray beam for high resolution X-ray fluorescence imaging
R Figueroa1, F Geser2, J López-Correa3
1Departamento de Ciencias Físicas, Universidad de La Frontera, Francisco Salazar, 1145, Temuco, Chile; Centro de Física e Ingeniería en Medicina - CFIM, Universidad de La Frontera, Francisco Salazar, 1145, Temuco, Chile.
Abstract:
The traditional X-ray tube design is built upon the impact of energetic electrons on high atomic number absorbers producing the X-ray output, consisting of photons due to Bremsstrahlung and fluorescence. Typically, electrons current hits the target within a limited area of a few millimeters square stopping the electrons, which lose their energy and produce the X rays constituting an inherently divergent beam. This geometrical property of traditional X-ray beams is responsible for several undesirable effects when trying to optimize applications requiring high incident fluence spatial concentration, like X-ray fluorescence imaging. This work presents a Monte Carlo study about a novel X-ray tube design, based on a cylindrical target that is capable of producing a convergent X-ray beam aimed at improving overall performance and spatial resolution in certain applications, like X-ray fluorescence imaging. Main design characteristics for relevant parts, like target/anode, filter, and collimator, have been carefully investigated by means of Monte Carlo simulation using two independent codes: FLUKA and PENELOPE. The obtained results suggest the feasibility of the proposed design remarking that high fluence concentration can be achieved, which can be particularly useful for further applications, like tumor targeting by X-ray fluorescence imaging by means of high atomic number nanoparticle infusion, as reported in this work.
More Related Videos
10:18Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography
Published on: February 21, 2017
07:48High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
Published on: September 30, 2022
Related Concept Videos
Super-resolution Fluorescence Microscopy
X-ray Imaging
Confocal Fluorescence Microscopy
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Scanning Electron Microscopy
Fundamental Principles
Accelerated...