In vivo application and validation of a novel noninvasive method to estimate the end-systolic elastance
Stamatia Pagoulatou1, Karl-Philipp Rommel2,3, Karl-Patrik Kresoja2,3
1Laboratory of Hemodynamics and Cardiovascular Technology, Institute of Bioengineering, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland.
Abstract:
Accurate assessment of the left ventricular (LV) systolic function is indispensable in the clinic. However, estimation of a precise index of cardiac contractility, i.e., the end-systolic elastance (Ees), is invasive and cannot be established as clinical routine. The aim of this work was to present and validate a methodology that allows for the estimation of Ees from simple and readily available noninvasive measurements. The method is based on a validated model of the cardiovascular system and noninvasive data from arm-cuff pressure and routine echocardiography to render the model patient-specific. Briefly, the algorithm first uses the measured aortic flow as model input and optimizes the properties of the arterial system model to achieve correct prediction of the patient's peripheral pressure. In a second step, the personalized arterial system is coupled with the cardiac model (time-varying elastance model) and the LV systolic properties, including Ees, are tuned to predict accurately the aortic flow waveform. The algorithm was validated against invasive measurements of Ees (multiple pressure-volume loop analysis) taken from n = 10 patients with heart failure with preserved ejection fraction and n = 9 patients without heart failure. Invasive measurements of Ees (median = 2.4 mmHg/mL, range = [1.0, 5.0] mmHg/mL) agreed well with method predictions (normalized root mean square error = 9%, ρ = 0.89, bias = -0.1 mmHg/mL, and limits of agreement = [-0.9, 0.6] mmHg/mL). This is a promising first step toward the development of a valuable tool that can be used by clinicians to assess systolic performance of the LV in the critically ill.NEW & NOTEWORTHY In this study, we present a novel model-based method to estimate the left ventricular (LV) end-systolic elastance (Ees) according to measurement of the patient's arm-cuff pressure and a routine echocardiography examination. The proposed method was validated in vivo against invasive multiple-loop measurements of Ees, achieving high correlation and low bias. This tool could be most valuable for clinicians to assess the cardiovascular health of critically ill patients.
More Related Videos
08:21Functional Assessment of the Donor Heart During Ex Situ Perfusion: Insights from Pressure-Volume Loops and Surface Echocardiography
Published on: October 11, 2022
09:05Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016