Related Experiment Video
Updated: Aug 19, 2026

Measurement of Factor V Activity in Human Plasma Using a Microplate Coagulation Assay
Published on: September 9, 2012
Monoclonal antibodies to human factor VII: a one step immunoradiometric assay for VII:Ag
T Takase1, E G Tuddenham, S Chand
1Academic Department of Haematology, Royal Free Hospital, London.
Three mouse monoclonal antibodies (RFF-VII/1, RFF-VII/2, and RFF-VII/3) which bind specifically to different epitopes on human factor VII antigen were raised. Two of the antibodies, RFF-VII/1 and RFF-VII/2, bound strongly to factor VII antigen (VII:Ag), but only RFF-VII/1 and RFF-VII/3 were potent inhibitors of factor VII coagulation activity (VII:C). RFF-VII/1 and RFF-VII/2 were used in a one step, double monoclonal immunoradiometric assay for VII:Ag. This was highly reproducible and detected as little as 0.05U/dl VII:Ag. Values for VII:Ag obtained for plasma samples from normal subjects (n = 20), patients with liver disease (n = 20), patients treated with warfarin (n = 20), and those congenitally deficient in factor VII (n = 7) correlated very well (r = 0.96) with data obtained in a radioimmunoassay using polyclonal rabbit antiserum to factor VII. This simple and sensitive monoclonal antibody based assay offers a convenient method for the detection of VII:Ag in various disease states.
Three mouse monoclonal antibodies (RFF-VII/1, RFF-VII/2, and RFF-VII/3) which bind specifically to different epitopes on human factor VII antigen were raised. Two of the antibodies, RFF-VII/1 and RFF-VII/2, bound strongly to factor VII antigen (VII:Ag), but only RFF-VII/1 and RFF-VII/3 were potent inhibitors of factor VII coagulation activity (VII:C). RFF-VII/1 and RFF-VII/2 were used in a one step, double monoclonal immunoradiometric assay for VII:Ag. This was highly reproducible and detected as little as 0.05U/dl VII:Ag. Values for VII:Ag obtained for plasma samples from normal subjects (n = 20), patients with liver disease (n = 20), patients treated with warfarin (n = 20), and those congenitally deficient in factor VII (n = 7) correlated very well (r = 0.96) with data obtained in a radioimmunoassay using polyclonal rabbit antiserum to factor VII. This simple and sensitive monoclonal antibody based assay offers a convenient method for the detection of VII:Ag in various disease states.
More Related Videos
08:30Investigating von Willebrand Factor Pathophysiology Using a Flow Chamber Model of von Willebrand Factor-platelet String Formation
Published on: August 14, 2017
08:50Thrombus Profiling Assay: A Microfluidics-Based Platform for Comprehensively Characterizing Biomechanical Thrombogenesis
Published on: January 9, 2026