Sonication improves microbiologic diagnosis of periprosthetic elbow infection
Laure Flurin1, Kerryl E Greenwood-Quaintance1, Ronda N Esper2
1Divisions of Clinical Microbiology and Infectious Diseases, Mayo Clinic, Rochester, MN, USA.
Background:
Periprosthetic joint infection (PJI) is a relatively frequent and oftentimes devastating complication after total elbow arthroplasty (TEA). Its microbiologic diagnosis is usually based on periprosthetic tissue culture (hereafter referred to as tissue culture), but the sensitivity of tissue culture is variable. Although implant sonication culture has been shown to be superior to tissue culture for the diagnosis of hip and knee PJI, only a single small study (of fewer than 10 infected implants) has assessed sonication for PJI diagnosis after elbow arthroplasty.
Methods:
We retrospectively analyzed 112 sonicate fluid cultures from patients who underwent revision of a TEA at a single institution between 2007 and 2019, comparing results to those of tissue cultures. We excluded patients who had fewer than 2 tissues submitted for culture. Using the Infectious Diseases Society of America guidelines to define PJI, there were 49 infected and 63 non-infected cases. Median ages in the PJI and non-infected groups were 66 and 61 years, respectively. In the non-infected group, 65% were female vs. 63% in the PJI group. We reviewed clinical characteristics and calculated the sensitivity and specificity of tissue compared with sonicate fluid culture. In addition, we compared the sensitivity of tissue culture to the combination of tissue and sonicate fluid culture.
Results:
The most common pathogens were coagulase-negative Staphylococcus sp (49%), followed by Staphylococcus aureus (12%). Sensitivity of tissue culture was 63%, and sensitivity of sonicate fluid culture was 76% (P = .109). Specificity of tissue culture was 94% and specificity of sonicate fluid culture was 100%. Sensitivity of sonicate fluid culture in combination with tissue culture was 84% (P = .002 compared to tissue culture alone).
Conclusion:
In this study, we found that the combination of sonicate fluid and tissue culture had a greater sensitivity than tissue culture alone for microbiologic diagnosis of PJI after TEA.
Insights
Diagnosing periprosthetic joint infection (PJI) after total elbow arthroplasty (TEA) is improved by combining sonicate fluid and tissue cultures. This dual approach offers higher sensitivity for detecting PJI compared to tissue culture alone.
Area of Science:
- Orthopedic Surgery
- Infectious Diseases
- Microbiology
Background:
- Periprosthetic joint infection (PJI) is a significant complication following total elbow arthroplasty (TEA).
- Current diagnostic methods, primarily tissue culture, have variable sensitivity for PJI detection.
- Limited research exists on implant sonication for diagnosing PJI specifically after elbow surgery.
Purpose of the Study:
- To evaluate the diagnostic performance of implant sonication fluid culture compared to traditional tissue culture for PJI after TEA.
- To determine if combining sonicate fluid and tissue cultures improves diagnostic sensitivity for PJI in the elbow.
Main Methods:
- Retrospective analysis of 112 sonicate fluid cultures from revision TEA cases (2007-2019).
- Comparison of sonicate fluid culture results with periprosthetic tissue cultures.
- Application of Infectious Diseases Society of America guidelines to classify PJI cases (49 infected, 63 non-infected).
Main Results:
- The most common pathogens identified were coagulase-negative Staphylococcus sp. (49%) and Staphylococcus aureus (12%).
- Sonicate fluid culture showed higher sensitivity (76%) than tissue culture (63%), with 100% specificity.
- The combination of sonicate fluid and tissue culture achieved a significantly higher sensitivity (84%) compared to tissue culture alone (P = .002).
Conclusions:
- Combining sonicate fluid and tissue culture enhances the microbiologic diagnosis of PJI after TEA.
- Implant sonication is a valuable adjunct to tissue culture for improving PJI detection in elbow arthroplasty revisions.
More Related Videos
04:37Author Spotlight: Advancing Research on Candida albicans Biofilm-Associated Prosthetic Joint Infections
Published on: February 2, 2024
07:48High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
Published on: September 30, 2022
Related Concept Videos
Acute Pyelonephritis II: Diagnostic Studies and Management
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Hand hygiene
Hand washing...
Urinary Tract Infection III: Diagnostic Studies and Interprofessional Care