Electrochemical Detection of Phosphate Ion in Body Fluids with a Magnesium Phosphate Modified Electrode
Qixuan Chen1, Shuquan Sun1, Guoxia Ran1
1International Research Center for Photoresponsive Molecules and Materials, School of Chemical and Material Engineering, Jiangnan University, 1800 Lihu Road, Wuxi, Jiangsu, 214122, P. R. China.
Abstract:
An electrochemical sensor for phosphate detection in body fluids was developed based on the hydration transition of magnesium hydrogen phosphate (newberyite, MgHPO4·3H2O). The sensor was fabricated through incubation of a multi-walled carbon nanotube/Nafion (MWCNT/Nafion) modified glassy carbon electrode (GCE) in magnesium phosphate solution, where MgHPO4·3H2O was self-assembled on the electrode surface (denoted as MgP/MWCNT/Nafion). An electrooxidation peak at 1.0 V vs. Ag/AgCl was observed when the as-prepared electrode was subjected to a differential pulse voltammetry (DPV) scan in the presence of phosphate in acetate solution. When the DPV scan was performed in 0.4 - 1.3 V vs. Ag/AgCl, a linear relationship was observed between the peak height and the phosphate concentration in the range from 0.01 to 25 μM in the presence of 0.1 mM Mg2+ in the acetate solution with a limit of detection of 32 nM. And the sensor was successfully applied for phosphate detection in human urine and saliva samples with recoveries of 94.7 - 104.4 and 96 - 103.3%, respectively.
More Related Videos
08:03Multi-analyte Biochip MAB Based on All-solid-state Ion-selective Electrodes ASSISE for Physiological Research
Published on: April 18, 2013
09:33Phthalic Acid Ester-Binding DNA Aptamer Selection, Characterization, and Application to an Electrochemical Aptasensor
Published on: March 21, 2018
Related Concept Videos
Potentiometry: Membrane Electrodes
Introduction to Electrolytes
Role of Sodium
One...
Phosphate Buffer
Sodium dihydrogen phosphate does not fully dissociate in neutral or acidic solutions. When a strong base, such as sodium hydroxide (NaOH), is introduced into the solution, sodium dihydrogen phosphate...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Electrodeposition
Electrodeposition can...
Capillary Electrophoresis: Instrumentation