X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
[Proposal for Reduction Measures of Eye Lens Exposure Based on Actual Exposure Management in Radiation-exposed
Toshioh Fujibuchi1, Katsuya Fujita2, Takayuki Igarashi3
1Department of Health Sciences, Faculty of Medical Sciences, Kyushu University.
Purpose:
To investigate the actual condition of the crystalline lens equivalent dose and effective dose according to the type of job and the type of duties in a medical institution. We also sought to clarify effective exposure reduction strategies.
Methods:
Equivalent crystalline lens doses, effective doses, job type, and duties for 8656 persons · year were obtained from 17 medical facilities. We analyzed the relationship between the effective dose and the crystalline lens equivalent dose in uniform exposure control and non-uniform exposure control conditions. Exposure data were obtained for 13 unique job types and duties.
Results:
The ratio of the lens equivalent dose to the effective dose of non-uniform exposure managers was 2 to 6 times and varied depending on the occupation. The percentage of persons whose annual lens equivalent dose exceeded 20 mSv was 4.75% for medical doctors, 1.17% for nurses, and 0.24% for radiological technologists. Highly exposed tasks included doctors in cardiology and gastroenterology performing angiography and endoscopy, nurses in endoscopy, and radiological technologists in radiography and CT examinations.
Conclusion:
Thorough unequal exposure control for operations with high crystalline lens exposure, radiation protection education, and effective use of proper personal protective equipment such as the use of radiation protection glasses may reduce lens exposure levels.
More Related Videos
06:31Precision Implementation of Minimal Erythema Dose MED Testing to Assess Individual Variation in Human Inflammatory Response
Published on: October 3, 2019
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Biological Effects of Radiation
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...