Related Experiment Video
Updated: Jun 27, 2026

Preparation and Pathogen Inactivation of Double Dose Buffy Coat Platelet Products using the INTERCEPT Blood System
Published on: December 7, 2012
Fatal sepsis associated with a storage container leak permitting platelet contamination with environmental bacteria
Emmanuel A Fadeyi1, Stephen J Wagner2, Corinne Goldberg2
1Department of Pathology and Laboratory Medicine, Wake Forest University School of Medicine Winston-Salem, Winston-Salem, North Carolina, USA.
Background:
Pathogen reduction technology and enhanced bacterial culture screening promise to significantly reduce the risk of transfusion-associated septic reactions due to contaminated platelets. Recent reports suggest that these interventions lack efficacy for post-collection and processing contamination with environmental organisms if the storage bag integrity is compromised.
Case Report:
We report a fatal septic transfusion reaction in a 63-year-old patient with chronic kidney and liver disease who received a pathogen reduced platelet transfusion in anticipation of surgery.
Methods:
The residual platelet concentrate was cultured, with the detected microorganisms undergoing 16S genotype sequencing. Separate pathogen reduction studies were performed on the recovered bacteria, including assessment for amotosalen photoproducts. The storage container was subjected to pressure testing and microscopic examination. Environmental culture screening was performed at the hospital.
Results:
Gram negative rods were detected in the platelet unit and cultures of both platelet component and the patient's blood grew Acinetobacter baumannii complex, Leclercia adecarboxylata and Staphylococcus saprophyticus. These strains were effectively inactivated with >7.2, 7.7, and >7.1 log10 kill, respectively. The platelet storage container revealed a leak visible only on pressure testing. Hospital environmental cultures were negative and the contamination source is unknown. A. baumannii complex and S. saprophyticus 16S genotyping sequences were identical to those implicated in a previously reported septic reaction.
Conclusion:
Findings are compatible with post-processing environmental contamination of a pathogen reduced platelet concentrate via a non-visible, acquired storage container leak. Efforts are warranted to actively prevent damage to, and detect defects in, platelet storage containers, and to store and transport components in clean environments.
More Related Videos
10:32Treatment of Platelet Products with Riboflavin and UV Light: Effectiveness Against High Titer Bacterial Contamination
Published on: August 24, 2015
07:30Design of Cecal Ligation and Puncture and Intranasal Infection Dual Model of Sepsis-Induced Immunosuppression
Published on: June 15, 2019
Related Concept Videos
Sources of Food Contamination
Microbial Bioremediation of Plastics
Reservoir of Infection
Staphylococcal Skin Infections
Bacterial Gastroenteritis
Clinical Significance of Antibiotic Resistance