Related Experiment Video
Updated: Nov 16, 2025

Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Is the detectability of the spot sign on CT angiography depending on slice thickness and reconstruction type?
Christiane Franz1, Dimah Hasan1, Ehsan Yousefian Jazi1
1Department of Diagnostic and Interventional Neuroradiology, University Hospital RWTH Aachen, Aachen, Germany.
Objective:
The spot sign is a validated imaging marker widely used in CT angiography (CTA) to detect active bleeding and a higher risk of hematoma expansion in patients with intracerebral hemorrhage (ICH). The aim of this study was to investigate the detectability of spot signs on thin multiplanar projection reconstruction (MPR) images compared to thicker maximum intensity projection (MIP) images.
Methods:
In this retrospective analysis, we assessed imaging data of 146 patients with primary hypertensive/microangiopathic ICH who received emergency non-contrast computed tomography (NCCT) and CTA. Two experienced radiologists, blinded to each other, evaluated images of thin (1 mm) MPR images and thick (3 mm) MIP images on the presence of spot signs and performed a consensus reading. Kappa tests were used for data comparison.
Results:
In total, spot signs were observed in 27 cases (=18.5 %) in both thin MPR and thick MIP slices. Detectability of the spot sign did not differ in 1 mm MPR images and 3 mm MIP images (Cohen's kappa, 1.0; p = 0.00). Also, when the readings of the two radiologists were analyzed separately, results for MPR and MIP slices were similar (MPR: Cohen's kappa, 0.81, p = 0.00; MIP: Cohen's kappa, 0.74; p = 0.00).
Conclusion:
No significant difference in the detectability of the spot sign could be demonstrated when comparing 1 mm MPR images with 3 mm MIP images.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
12:39DUCT: Double Resin Casting followed by Micro-Computed Tomography for 3D Liver Analysis
Published on: September 28, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT