Objective:
To describe the developmental anatomy of the eustachian tube (ET) and its relationship to surrounding structures on computed tomography.
Study Design:
Case series with chart review.
Setting:
A tertiary care hospital.
Methods:
ET anatomy was assessed with reformatted high-resolution computed tomography scans from 2010 to 2018. Scans (n = 78) were randomly selected from the following age groups: <4, 5 to 7, 8 to 18, and >18 years. The following were measured and compared between groups: ET length, angles, and relationship between its bony cartilaginous junction and the internal carotid artery and between its nasopharyngeal opening and the nasal floor.
Results:
The distance between the bony cartilaginous junction and internal carotid artery decreased with age between the <4-year-olds (2.4 ± 0.6 mm) and the 5- to 7-year-olds (2.0 ± 0.3 mm, P = .001). The ET length increased among the <4-year-olds (32 mm), 5- to 7-year-olds (36 mm), and 8- to 18-year-olds (41 mm, P < .0001). The cartilaginous ET increased among the <4-year-olds (20 mm), 5- to 7-year-olds (25 mm), and 8- to 18-year-olds (28 mm, P < .0001). The ET horizontal angle increased among the <4-year-olds (17°), 5- to 7-year-olds (21°), and 8- to 18-year-olds (23°, P≤ .003), but the ET sagittal angle did not statistically change after 5 years of age. The height difference between the nasopharyngeal opening of the ET and the nasal floor increased among the <4-year-olds (4 mm), 5- to 7-year-olds (7 mm), and 8- to 18-year-olds (11 mm, P < .0001).
Conclusion:
The ET elongates with age, and its angles and relationship to the nasal floor increase. Although some parameters mature faster, more than half of the ET growth occurs by 8 years of age, and adult morphology is achieved by early adolescence.