Related Experiment Video
Updated: Nov 16, 2025

Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement
Published on: March 26, 2018
Clinical study of minimally invasive aortic valve replacement through a right parasternal second intercostal
Feng Lu1, Shu-Qiang Zhu1, Xiang Long1
1Department of Cardiothoracic Surgery, The Second Affiliated Hospital of Nanchang University, Nanchang, PR China.
Background:
There is an increasing demand for minimally invasive aortic valve replacement. This study aimed to investigate the safety and feasibility of minimally invasive aortic valve replacement through a right parasternal second intercostal transverse incision.
Methods:
This was a retrospective study, and we collected information from 111 patients who underwent isolated aortic valve replacement surgery performed by the same surgeon from January 2018 to December 2019. According to the operative approach, the patients were divided into a sternotomy aortic valve replacement (SAVR) group (n = 62) and a minimally invasive aortic valve replacement (Mini-AVR) group (n = 49). We compared the intraoperative and postoperative data between the two groups.
Result:
There was no difference in preoperative data between the Mini-AVR and SAVR. The postoperative ventilator-assisted time, CSICU time and postoperative hospital stay of the Mini-AVR were shorter than those of the SAVR [(15.45 ± 5.75) VS (18.51 ± 6.71) h; (1.77 ± 0.31) VS (2.04 ± 0.63) d; (8.69 ± 2.75) VS (10.77 ± 2.94) d], and the difference was statistically significant (P < 0.05). Mini-AVR had lower postoperative drainage and blood transfusion rates in the first 24 h than SAVR [(109.86 ± 125.98) VS (508.84 ± 311.70) ml; 22.4% VS 46.8%], and the differences were statistically significant (P < 0.05). The incidence of postoperative AF in the Mini-AVR group was also lower than that in the SAVR group (10.2% VS 30.6%), and the differences were statistically significant (P < 0.05).
Conclusion:
Mini-AVR has the advantages of less ventilator time, a reduced need for blood transfusion, less AF and a faster recovery. Mini-AVR is a safe and feasible surgical technique that is worthy of clinical application.
More Related Videos
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
08:42Cox-Maze IV Procedure Concomitant with Valvular Surgery In Situs Inversus Dextrocardia: A Single-Center Experience in China
Published on: February 11, 2022