Combination of different chromatographic and sampling modes for high-resolution mass spectrometric screening of
Verónica Castro1, José Benito Quintana2, Inmaculada Carpinteiro1
1Department of Analytical Chemistry, Institute of Research on Chemical and Biological Analysis (IAQBUS), Universidade de Santiago de Compostela, 15782, Santiago de Compostela, Spain.
Abstract:
This study explores the combination of two sampling strategies (polar organic compounds integrative sampler (POCIS) vs. spot sampling) and four chromatographic retention modes (reversed-phase liquid chromatography (RPLC), hydrophilic interaction liquid chromatography (HILIC), mixed-mode liquid chromatography (MMLC) and supercritical fluid chromatography (SFC)) for high-resolution mass spectrometry (HRMS) screening of organic pollutants in water samples. To this end, a suspect screening approach, using iterative data-dependent tandem mass spectrometry (MS/MS) driven by a library of 3227 chemicals (including pharmaceuticals, pesticides, drugs of abuse, human metabolites, industrial chemicals and other pollutants), was employed. Results show that POCIS can afford a larger number of positive identifications as compared to spot sampling. On the other hand, the best suited retention mechanisms, in terms of identified analytes, are SFC, and followed by RPLC, MMLC and HILIC. However, the best combination (POCIS + SFC) would only allow the identification of 67% of the detected analytes. Thus, the combination of the two sampling strategies, spot and passive sampling, with two orthogonal retention mechanisms, RPLC and SFC, is proposed in order to maximize the number of analytes detected (89%). This strategy was applied to different surface water (river and estuary) samples from Galicia (NW Spain). A total of 155 compounds were detected at a confidence level 2a, from which the major class was pharmaceuticals (61%).
More Related Videos
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
High-Resolution Mass Spectrometry (HRMS)
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...