A novel internal cold circulation radiofrequency-assisted device for liver transection
Yanzhao Zhou1, Jingzhong Ouyang1, Zhengzheng Wang1
1Department of Hepatopancreatobiliary Surgery, The Affiliated Tumor Hospital of Zhengzhou University, Henan, People's Republic of China.
Summary
The new internal cold circulation bipolar radiofrequency (New-RF) offers a safer and more effective method for liver tumor resection compared to Habib-4X. This advanced radiofrequency device demonstrates faster resection speeds and reduced complications, improving patient outcomes.
Area of Science:
- Hepatobiliary Surgery
- Minimally Invasive Oncology
- Radiofrequency Ablation Technologies
Background:
- Hepatocellular carcinoma (HCC) is a significant global health concern.
- Radiofrequency-assisted liver resection (RALR) is a common surgical approach for HCC.
- Optimizing RALR devices is crucial for improving surgical outcomes and patient safety.
Purpose of the Study:
- To compare the safety and efficacy of a novel internal cold circulation bipolar radiofrequency device (New-RF) against the established Habib-4X bipolar radiofrequency device.
- To evaluate the performance of New-RF in liver tumor resection, focusing on key surgical parameters.
Main Methods:
- A retrospective study of 85 patients with HCC undergoing RALR between February 2017 and January 2020.
- Patients were divided into two groups: 45 receiving New-RF and 40 receiving Habib-4X.
- Primary outcome measures included liver transection speed, coagulation width, hemorrhage volume, transfusion rate, and operation time.
Main Results:
- New-RF demonstrated a significantly faster liver transection speed (4.81 cm²/min vs 3.64 cm²/min) and shorter operation time (55.04 min vs 64.02 min) compared to Habib-4X.
- The New-RF group exhibited a narrower coagulation width (1.42 cm² vs 1.81 cm²) and a lower rate of needle path bleeding (13.3% vs 35.0%).
- A significantly lower carbonization rate of the electrode needle was observed with New-RF (22.2% vs 77.8%).
Conclusions:
- The new internal cold circulation bipolar radiofrequency device is a safe and effective auxiliary tool for liver resection.
- New-RF offers advantages over Habib-4X, including faster resection, reduced electrode needle carbonization, and more precise coagulation.
- This technology holds promise for improving the efficiency and safety of radiofrequency-assisted liver resection.
Keywords:
Primary hepatocellular carcinomacold circulationhemorrhagehepatic resectionradiofrequency auxiliary