Related Experiment Video
Updated: Nov 16, 2025

Application of a New Mesh Fixation Method in Laparoscopic Incisional Hernia Repair
Published on: December 23, 2022
Prophylactic Mesh Reinforcement for Prevention of Midline Incisional Hernias: A Publication Bias Adjusted
Oscar A Olavarria1,2, Naila H Dhanani1,2, Karla Bernardi1,2
1Department of Surgery, Lyndon B. Johnson General Hospital, McGovern Medical School at UTHealth, Houston, Texas.
Objective:
To systematically review the published literature on the use of prophylactic mesh reinforcement of midline laparotomy closures for prevention of VIH.
Summary Of Background Data:
VIH are common complications of abdominal surgery. Prophylactic mesh has been proposed as an adjunct to prevent their occurrence.
Methods:
PubMed, Embase, Scopus, and Cochrane were reviewed for RCTs that compared prophylactic mesh reinforcement versus conventional suture closure of midline abdominal surgery. Primary outcome was the incidence of VIH at postoperative follow-up ≥24 months. Secondary outcomes included surgical site infection and surgical site occurrence (SSO). Pooled risk ratios were obtained through random effect meta-analyses and adjusted for publication bias. Network meta-analyses were performed to compare mesh types and locations.
Results:
Of 1969 screened articles, 12 RCTs were included. On meta-analysis there was a lower incidence of VIH with prophylactic mesh [11.1% vs 21.3%, Relative risk (RR) = 0.32; 95% confidence interval (CI) = 0.19-0.55, P < 0.001), however, publication bias was highly likely. When adjusted for this bias, prophylactic mesh had a more conservative effect (RR = 0.52; 95% CI = 0.39-0.70). There was no difference in risk of surgical site infection (9.1% vs 8.9%, RR = 1.08, 95% CI = 0.82-1.43; P = 0.118), however, prophylactic mesh increased the risk of SSO (14.2% vs 8.9%, RR = 1.57, 95% CI = 1.19-2.05; P < 0.001).
Conclusion:
Current RCTs suggest that in mid-term follow-up prophylactic mesh prevents VIH with increased risk for SSO. There is limited long-term data and substantial publication bias.