External validation of the clinical chemistry score
Karin Wildi1, Jasper Boeddinghaus2, Thomas Nestelberger2
1Cardiovascular Research Institute Basel (CRIB) and Department of Cardiology, University Hospital Basel, University of Basel, Switzerland; GREAT Network; Critical Care Research Group, The Prince Charles Hospital, Brisbane, and the University of Queensland, Brisbane, Australia.
Background:
Combining high-sensitivity cardiac troponin (hs-cTn) with estimated glomerular filtration rate and glucose within the Clinical Chemistry Score (CCS) could help in the assessment of patients with suspected acute myocardial infarction (AMI).
Methods:
In patients presenting with suspected AMI to the emergency department, we aimed to externally validate the performance of the CCS in a prospective international multicenter study and to directly compare the diagnostic and prognostic performance of the CCS with hs-cTnT and hs-cTnI baseline levels alone using a single cut-off approach. The diagnostic endpoint was diagnostic accuracy for AMI as centrally adjudicated by two independent cardiologists including cardiac imaging and serial hs-cTnT/I measurements. The prognostic endpoint was 30-day AMI or death.
Results:
AMI was the final diagnosis in 620/3827 patients (16.2%) adjudicated with hs-cTnT and 599 patients (15.7%) adjudicated with hs-cTnI. The CCS resulted in high diagnostic accuracy for AMI and prognostic accuracy for 30-days AMI/death as quantified by the area under the receiver-operating characteristic curve (AUC), using hs-cTnT 0.90 (95%CI 0.89-0.91) and 0.89 (95%CI 0.88-0.90), using hs-cTnI 0.91 (95%Cl 0.90-0.92) and 0.90 (95%CI 0.89-0.91) respectively. E.g. a CCS of 0 points resulted in a sensitivity of 99.8% (95%CI 99.1-100%) for rule-out of index AMI and 99.5% (95%CI 98.5-100%) for AMI/death at 30 days for hs-cTnT and 99.8% (95%CI 98.9-100%) and 99.6% (95%CI 98.6-100%) using hs-cTnI. Overall, the single hs-cTnT/I measurement approach provided comparable diagnostic (sensitivity 99.5-99.7%) and prognostic (sensitivity 98.9-99.5%) performance versus the CCS.
Interpretation:
The CCS provided high diagnostic and prognostic performance also in this independent large validation cohort. A single hs-cTnT/I measurement approach for rule-out MI yielded similar estimates.
More Related Videos
06:50A High-Throughput Electrochemiluminescence 7-Plex Assay Simultaneously Screening for Type 1 Diabetes and Multiple Autoimmune Diseases
Published on: May 29, 2020
06:16Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Related Concept Videos
Data Validation
Key parameters for method validation include:
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
z Scores and Area Under the Curve
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Critical Region, Critical Values and Significance Level
In hypothesis testing, a sample statistic is converted to a test statistic using z, t, or chi-square distribution. A critical region is an area under the curve in probability distributions demarcated by the critical value. When the test statistic falls in this region, it suggests that the null hypothesis must be rejected. As this region contains all those values of the...