Related Experiment Video
Updated: Nov 16, 2025

High-Resolution Respirometry in a Small-Volume Chamber
Published on: July 25, 2025
Validity and reproducibility of VO2 max testing in a respiration chamber
Jordi P D Kleinloog1, Stephen P G A van Laar1, Paul F M Schoffelen1
1Department of Nutrition and Movement Sciences, NUTRIM School of Nutrition and Translational Research in Metabolism, Maastricht University Medical Centre +, Maastricht, The Netherlands.
Abstract:
The aim of this study was to investigate whether VO2 max can be accurately measured in a respiration chamber. Thirty participants aged 23.4 ± 3.9 years with a wide range in VO2 max were included. Participants performed four incremental cycle ergometer tests (VO2 max) with a minimum of 5 days between tests. These tests consisted of one familiarization test with face mask, followed by two VO2 max tests in the respiration chamber and one test with face mask in randomized order. Oxygen consumption and CO2 production were measured continuously using Omnical (Maastricht University, the Netherlands) gas analysis system. The mean VO2 max was 3634 ± 766 ml, which resulted in mean VO2 max per lean body mass of 60.8 ± 8.0 ml/kg. Repeated respiration chamber tests showed a high concordance, and no significant differences were detected between tests (Lin's concordance correlation coefficient (Rc) = 0.99; ∆70 ± 302 ml/min; p = .38). There was high concordance between the mean VO2 max from both respiration chamber tests and the mean face mask tests, and no significant difference (Rc = 0.99; ∆41 ± 173 ml/min; p = .22) was observed. The Bland-Altman plots showed no proportional bias between different tests. In conclusion, the respiration chamber has been found to be a valid and reproducible method for measuring VO2 max. New research opportunities are possible in the respiration chamber, such as maximal exercise testing during 24-hour measurements.
More Related Videos
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
07:26Conducting Maximal and Submaximal Endurance Exercise Testing to Measure Physiological and Biological Responses to Acute Exercise in Humans
Published on: October 17, 2018
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Respiratory Volumes and Capacities
Respiratory Volumes and Capacities I