Related Experiment Video
Updated: Nov 16, 2025

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
Thoracic aortic stent graft placement and simultaneous screw removal for a screw hitting the aorta
Seimei Go1, Shingo Mochizuki1, Kazunori Yamada1
1Akane-Foundation Tsuchiya General Hospital, Department of Cardiovascular Surgery, Japan.
Abstract:
Vascular injury caused by spinal screw displacement is a rare complication of spinal fusion surgery. Here, we report a case with no perforation of the aortic wall, which we treated by means of simultaneous thoracic endovascular aorta repair (TEVAR) and screw removal. An 82-year-old female underwent corrective spinal fixation. Postoperatively, a screw became displaced from the vertebrae and contacted the outer membrane of the descending aorta. To prevent rupture of the aorta, we performed stent graft placement from the right common femoral aorta. We left a flexion-resistant catheter in the left arm and moved the patient into an abdominal position with the left arm extended upward to enable immediate insertion of a guidewire and occlusion balloon if necessary. Then we removed the displaced screw with a drill. This safe and effective method can prevent possible aortic injuries secondary to displaced spinal screws. The key to our method is the simultaneous performance of TEVAR and screw removal, made possible through patient repositioning.