Related Experiment Video
Updated: Nov 15, 2025

Effects of Different Connection Modes of Electroacupuncture on Electrocardiogram and Nerve Discharge in Rats
Published on: January 3, 2025
Effect of noise on the electrocardiographic parameters
Mustafa Begenc Tascanov1, Suzan Havlioglu2, Zulkif Tanriverdi3
1Department of Cardiology, Faculty of Medicine, Harran University, Sanliurfa, Turkey. drbegenc@gmail.com.
Purpose:
Noise, defined as any sound that is unpleasant, is one of the most important environmental problems. Prolonged exposure to noise has been shown to be associated with the development of cardiovascular diseases. No study investigated the effect of noise on surface electrocardiography (ECG).
Aims:
The aim of our study is to investigate the effect of noise on surface ECG parameters including P-wave dispersion (PWD), QT intervals, corrected QT interval (QTc), T-wave peak to end (Tp-e) interval, and Tp-e/QT and Tp-e/QTc ratios.
Methods:
A total of 51 people working in the textile factory affected by the noise and 43 volunteers without any disease and who were not exposed to noise were included in this study. The average noise level in the textile factory was 112 dB. A 12-lead ECG was obtained from all individuals. PR interval, PWD, QRS duration, QT interval, QTc interval, Tp-e interval, and Tp-e/QT and Tp-e/QTc ratios were calculated for all individuals.
Results:
The noise group had significantly increased PWD [35 (28-40) vs. 28 (22-36) p = 0.029], QT interval ( 373.5 ± 27.3 vs. 359.3 ± 2.74, p = 0.001), QTc interval [(409 ± 21 vs. 403 ± 13 p = 0.045)], Tp-e interval [(90.6 ± 6.0 vs. 83.5 ± 7.3 p < 0.001)], Tp-e/QT [(0.24 ± 0.03 vs. 0.23 ± 0.02, p = 0.015)] and Tp-e/QTc [(0.22 ± 0.02 vs. 0.21 ± 0.02 p < 0.001)] compared to control group. Also, duration of working was positively correlated with PWD (r = 0.468, p = 0.001) and Tp-e/QTc ratio (r = 0.328, p = 0.019). In multiple linear regression linear regression analysis, noise was the independent predictor of both PWD (β = 0.244, p = 0.032) and Tp-e/QTc (β = 0.319, p = 0.003) CONCLUSION: We showed that noise significantly increased PWD, QT and Tp-e interval measurements. Also, noise was the independent predictor for both PWD and Tp-e/QTc.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Electrophysiology of Normal Cardiac Rhythm
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
ECG Interpretation of Arrhythmias I: Sinus Arrhythmias
Types of Arrhythmias
Sinus Node Arrhythmias
Sinus Bradycardia: Originating from the sinoatrial (SA) node, sinus bradycardia involves slower impulses, resulting in a heart rate of less than 60 beats per minute (bpm). Causes include sleep, vagal stimulation, beta-blockers, hypothyroidism,...

