Related Experiment Video
Updated: Nov 15, 2025

Fluorescence Recovery after Merging a Droplet to Measure the Two-dimensional Diffusion of a Phospholipid Monolayer
Published on: October 15, 2015
Line-FRAP, A Versatile Method to Measure Diffusion Rates In Vitro and In Vivo
Debabrata Dey1, Shir Marciano1, Ariane Nunes-Alves2
1Department of Biomolecular Sciences, Weizmann Institute of Science, Israel.
Abstract:
The crowded cellular milieu affect molecular diffusion through hard (occluded space) and soft (weak, non-specific) interactions. Multiple methods have been developed to measure diffusion coefficients at physiological protein concentrations within cells, each with its limitations. Here, we show that Line-FRAP, combined with rigours data analysis, is able to determine diffusion coefficients in a variety of environments, from in vitro to in vivo. The use of Line mode greatly improves time resolution of FRAP data acquisition, from 20-100 Hz in the classical mode to 800 Hz in the line mode. This improves data analysis, as intensity and radius of the bleach at the first post-bleach frame is critical. We evaluated the method on different proteins labelled chemically or fused to YFP in a wide range of environments. The diffusion coefficients measured in HeLa and in E. coli were ~2.5-fold and 15-fold slower than in buffer, and were comparable to previously published data. Increasing the osmotic pressure on E. coli further decreases diffusion, to the point at which proteins virtually stop moving. The method presented here, which requires a confocal microscope equipped with dual scanners, can be applied to study a large range of molecules with different sizes, and provides robust results in a wide range of environments and protein concentrations for fast diffusing molecules.
More Related Videos
15:10From Fast Fluorescence Imaging to Molecular Diffusion Law on Live Cell Membranes in a Commercial Microscope
Published on: October 9, 2014
10:33A Method for Determination and Simulation of Permeability and Diffusion in a 3D Tissue Model in a Membrane Insert System for Multi-well Plates
Published on: February 23, 2018
Related Concept Videos
Protein Diffusion in the Membrane
Methods for Studying Drug Absorption: In vitro
The diffusion cell method uses a two-compartment cell, including a donor compartment with the drug solution, which simulates the environment where the drug is applied, and a receptor compartment with a buffer solution, which simulates the environment...
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Methods for Studying Drug Absorption: In situ
The Doluisio method involves perfusing a prepared segment of a rat's small intestine with a solution of radiolabeled drug and a non-absorbable marker. This helps to differentiate between absorbed and non-absorbed drug concentrations. The intestinal segment is connected at both ends using tubing and syringes,...