Thermoplastic nanofluidic devices for identifying abasic sites in single DNA molecules

Swarnagowri Vaidyanathan1, Kumuditha M Weerakoon-Ratnayake2, Franklin I Uba3

  • 1Bioengineering Program, The University of Kansas, Lawrence, KS 66045, USA and Center of BioModular Multiscale Systems for Precision Medicine, Lawrence, KS 66047, USA.

Lab on a Chip
|March 2, 2021
PubMed

Insights

A novel single-molecule assay on nanofluidic chips detects abasic (AP) sites in DNA, overcoming limitations of traditional methods for liquid biopsies and drug efficacy testing.

Area of Science:

  • Molecular Biology
  • Biophysics
  • Nanotechnology

Background:

  • DNA damage, including abasic (AP) sites, is a key indicator of therapeutic drug efficacy.
  • Existing DNA damage assays require large DNA quantities, limiting liquid biopsy applications.
  • Liquid biopsies are increasingly important for in vitro diagnostics but face DNA mass constraints.

Purpose of the Study:

  • To develop a sensitive single-molecule DNA damage assay for detecting AP sites.
  • To overcome the DNA mass limitations of liquid biopsies for diagnostic assays.
  • To enable direct measurement of AP sites in double-stranded (ds) DNA.

Main Methods:

  • Utilized plastic nanofluidic chips with nanochannels near DNA's persistence length to stretch single dsDNA molecules.
  • Employed input funnels, entropic traps, and stretching nanochannels for high-throughput processing.
  • Labeled dsDNA with an intercalating dye and a biotinylated aldehyde reactive probe (bARP) for dual-color fluorescence detection of DNA length and AP sites.

Main Results:

  • Successfully detected AP sites in single dsDNA molecules using a nanofluidic chip.
  • Quantified AP site frequency by detecting fluorescently-labeled streptavidin binding to bARP.
  • Demonstrated a method compatible with the low DNA input from liquid biopsies.

Conclusions:

  • The developed single-molecule assay effectively detects AP sites in dsDNA.
  • This nanofluidic approach offers a sensitive and high-throughput method for DNA damage assessment.
  • The assay is suitable for analyzing DNA damage in challenging samples like liquid biopsies.

Related Concept Videos