Related Experiment Video
Updated: Nov 15, 2025

Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
Monte Carlo study of patient and medical staff radiation exposures during interventional cardiology
1Higher Institute of Medical Technologies of Tunis, Tunis El Manar University, Tunisia; Nuclear Physics and High Energy Unit, Faculty of Sciences of Tunis, Tunis El Manar University, Tunisia.
Abstract:
The aim of this study is to assess the radiation exposure of the patient and the medical staff during interventional cardiology procedures. Realistic exposure scenarios were developed using the adult reference anthropomorphic phantoms adopted by the International Commission on Radiological Protection (ICRP110Male and ICRP110Female), and the radiation transport code Geant4 (version 10.3). The calculated equivalent and effective doses were normalised by the simulated Kerma-Area Product (KAP), resulting in two conversion coefficients HT/KAP and E/KAP. To properly evaluate the risk of exposure, several dose-dependent parameters have been investigated, namely: radiological parameters (tube kilovoltage peak (kVp), type of projection, field size (FOV)), and operator positions. Four projections (AP,PA,LAO25° and RAO25°) were simulated for three X-ray energy spectra (80,100 and 120 kVp) with four different values of FOV (15×15 cm2,20×20 cm2,25×25 cm2 and 30×30 cm2). The results showed that the conversion coefficients values increase with increasing tube voltage as well as the FOV size. Recommended projection during the interventional cardiology procedures, whenever possible, should be the PA projection rather than AP projection. The most critical projection for the patient and the main operator is the RAO25° projection and the LAO25° projection respectively. The comparison of our results with the literature data showed good agreement allowing their use in the dosimetric characterization of interventional cardiology procedures.
More Related Videos
11:38Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System IV: CMRI
Cardiac Catheterization I: Pre-Procedure Overview
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Cardiac Catheterization IV: Nursing Management