Related Experiment Video
Updated: Nov 15, 2025

Author Spotlight: Advancements in Multiplex Detection of Respiratory Viruses
Published on: November 10, 2023
Communication: Comparison of Respiratory Specimens for the Detection of SARS-CoV-2
Jee-Soo Lee1, Myoung-Seock Seo1, Tae-Rin Gwon1
1Department of Laboratory Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.
Abstract:
We compared SARS-CoV-2 detection rate of different respiratory specimens (nasopharyngeal swab [NPS], n=92; oropharyngeal swab [OPS], n=18; sputum, n=11). We also compared cycle threshold (Ct) values of paired specimen types obtained from the same patient on the same day. Then we characterized viral load kinetics of NPS (n=142), OPS (n=126), and sputum (n=75), during disease course. Sputum samples showed higher detection rate than NPS, and OPS exhibited the lowest detection rate. The median Ct values in NPS were significantly lower than in paired OPS, and higher than in paired sputum, respectively (P<0.05). During the disease course, viral load was the lowest in OPS and the highest in sputum samples.