Related Experiment Video
Updated: Nov 15, 2025

A Modified Sonographic Algorithm for Image Acquisition in Life-Threatening Emergencies in the Critically Ill Newborn
Published on: April 7, 2023
Integrating Focused Cardiac Ultrasound Into Pediatric Septic Shock Assessment
Sara Arnoldi1, Christie L Glau2,3, Sarah B Walker4
1Department of Clinical-Surgical Diagnostic and Pediatric Sciences, University of Pavia, Pavia, Italy.
Objectives:
To assess focused cardiac ultrasound impact on clinician hemodynamic characterization of patients with suspected septic shock as well as expert-generated focused cardiac ultrasound algorithm performance.
Design:
Retrospective, observational study.
Setting:
Single-center, noncardiac PICU.
Patients:
Less than 18 years old receiving focused cardiac ultrasound study within 72 hours of sepsis pathway initiation from January 2014 to December 2016.
Interventions:
Hemodynamics of patients with suspected septic shock were characterized as fluid responsive, myocardial dysfunction, obstructive physiology, and/or reduced systemic vascular resistance by a bedside clinician before and immediately following focused cardiac ultrasound performance. The clinician's post-focused cardiac ultrasound hemodynamic assessments were compared with an expert-derived focused cardiac ultrasound algorithmic hemodynamic interpretation. Subsequent clinical management was assessed for alignment with focused cardiac ultrasound characterization and association with patient outcomes.
Measurements And Main Results:
Seventy-one patients with suspected septic shock (median, 4.7 yr; interquartile range, 1.6-8.1) received clinician performed focused cardiac ultrasound study within 72 hours of sepsis pathway initiation (median, 2.1 hr; interquartile range, -1.5 to 11.8 hr). Two patients did not have pre-focused cardiac ultrasound and 23 patients did not have post-focused cardiac ultrasound hemodynamic characterization by clinicians resulting in exclusion from related analyses. Post-focused cardiac ultrasound clinician hemodynamic characterization differed from pre-focused cardiac ultrasound characterization in 67% of patients (31/46). There was substantial concordance between clinician's post-focused cardiac ultrasound and algorithm hemodynamic characterization (33/48; κ = 0.66; CI, 0.51-0.80). Fluid responsive (κ = 0.62; CI, 0.40-0.84), obstructive physiology (к = 0.87; CI, 0.64-1.00), and myocardial dysfunction (1.00; CI, 1.00-1.00) demonstrated substantial to perfect concordance. Management within 4 hours of focused cardiac ultrasound aligned with algorithm characterization in 53 of 71 patients (75%). Patients with aligned management were less likely to have a complicated course (14/52, 27%) compared with misaligned management (8/19, 42%; p = 0.25).
Conclusions:
Incorporation of focused cardiac ultrasound in the evaluation of patients with suspected septic shock frequently changed a clinician's characterization of hemodynamics. An expert-developed algorithm had substantial concordance with a clinician's post-focused cardiac ultrasound hemodynamic characterization. Management aligned with algorithm characterization may improve outcomes in children with suspected septic shock.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...

