Related Experiment Video
Updated: Nov 15, 2025

Using Cyclic Voltammetry, UV-Vis-NIR, and EPR Spectroelectrochemistry to Analyze Organic Compounds
Published on: October 18, 2018
Nonenzymatic Electrochemical Detection of 2,4,6-Trichlorophenol Using CuO/Nafion/GCE: A Practical Sensor for
Jamil A Buledi1, Amber R Solangi1, Saima Q Memon2
1National Centre of Excellence in Analytical Chemistry, University of Sindh, 76080 Jamshoro, Pakistan.
Abstract:
2,4,6-Trichlorophenol (2,4,6 TCP) is one of the hazardous toxicants, which has severe impacts on the environment and human health. This study is designed to develop a highly sensitive and selective electrochemical sensor based on CuO nanostructures for the detection of 2,4,6 TCP. The CuO nanostructures were synthesized through an aqueous chemical growth method and characterized by versatile analytical techniques, for example, Fourier transform infrared spectroscopy, field emission scanning electron microscopy, atomic force microscopy, energy-dispersive spectrometry, and X-ray diffraction. The characterization tools revealed a high crystalline nature, exceptional phase purity, nanoball morphology with an average size of around 18.7 nm for the CuO nanostructures. The synthesized material was used to modify a glassy carbon electrode (GCE) with the help of Nafion as a binder to improve its efficiency and sensitivity. The CuO/Nafion/GCE was proven to be a potential sensor for the determination of 2,4,6 TCP under optimized conditions at a scan rate of 70 mV/s, potential range of 0.1-1.0 V, and phosphate buffer of neutral pH as the supporting electrolyte. The linear range for 2,4,6 TCP was set from (1 to 120 μM) with a low limit of detection value calculated to be 0.046 μM. The developed sensor was effectively applied for water samples with acceptable recovery values from 95.9 to 100.6%.
Related Concept Videos
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Gas Chromatography: Types of Detectors-II
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...