Purpose:
18F-FDG PET myocardial metabolic imaging is used to estimate myocardial viability. However, poor image quality can affect the accurate quantification of viable myocardium. We assessed the feasibility of a rescue protocol that reinjected low-dose 18F-FDG with simultaneous 1 to 2 U of insulin injection and oral administration of 10 g of glucose to improve the image quality of 18F-FDG PET myocardial metabolic imaging.
Patients And Methods:
Fifty-one consecutive patients with poor quality to uninterpretable 18F-FDG PET/CT myocardial metabolic images received the rescue protocol immediately after the initial image acquisition. The postrescue image acquisition was performed 1 hour later. The rescue image quality was compared with the initial image. The qualitative visual estimation of the images was graded as follows: grade 0, homogeneous, minimal uptake; grade 1, predominantly minimal or mild uptake; grade 2, moderate uptake; and grade 3, good uptake. The myocardium-to-blood pool activity ratio (M/B) was measured to assess the image quality quantitatively.
Results:
The grades of 0 to 3 were observed in 24 (47%), 27 (53%), 0 (0%), and 0 (0%) patients, respectively, for the initial imaging, and in 0 (0%), 3 (5.9%), 4 (7.8%), and 44 (86.3%) patients for the rescue imaging (P < 0.001). The rescue M/B was significantly higher than the initial M/B (3.4 ± 1.4 vs 1.6 ± 0.6, respectively; P < 0.001).
Conclusions:
The rescue protocol successfully and rapidly improved the quality of myocardial 18F-FDG metabolic imaging.
More Related Videos
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT