[Reproducibility Analysis of Iodine Concentrations of Abdominal Parenchymal Organs Based on Spectral CT]

Qing Lin Meng1, Huan Xu1, Lin Xiong Zong1

  • 1Department of Radiology,Hainan Hospital of PLA General Hospital,Sanya,Hainan 572013,China.

Objective To investigate the intra-and inter-observer reproducibility of iodine concentrations of abdominal parenchymal organs based on spectral CT.Methods The water-free iodine images of the venous phase were retrospectively obtained from 50 patients with abdominal dynamic spectral CT scans.The iodine concentrations were measured in the left,right and caudate lobes of liver,spleen,pancreas and bilateral kidneys.Intraclass correlation coefficient(ICC)and Bland-Altman plot were employed to analyze the intra-and inter-observer reproducibility.Results The intra-observer ICCs of the left,right and caudate lobes of liver,spleen,pancreas,and left and right kidneys were 0.938(0.894,0.965),0.932(0.884,0.961),0.939(0.895,0.965),0.947(0.909,0.970),0.912(0.851,0.949),0.946(0.906,0.969)and 0.907(0.842,0.946),which indicated good intra-observer reproducibility.The inter-observer ICCs of the left,right and caudate lobes of liver,spleen,pancreas,and left and right kidneys were 0.947(0.909,0.970),0.927(0.875,0.958),0.943(0.902,0.968),0.956(0.924,0.975),0.934(0.887,0.962),0.927(0.875,0.958)and 0.892(0.818,0.937),which indicated good inter-observer reproducibility.Bland-Altman plots presented that more than 95% points of the intra-observer differences located within 95% CI of limits of agreement for the caudate lobe of liver,spleen,pancreas and bilateral kidneys,which was same as inter-observer differences of the caudate lobe of liver,spleen and right kidney.Conclusion The iodine concentration measurement based on the spectral CT presented good intra-and inter-observer reproducibility for the caudate lobe of liver and spleen.

Related Concept Videos

Radiological Investigation I: X-ray and CT01:30

Radiological Investigation I: X-ray and CT

Radiological investigations, including X-rays and computed tomography (CT) scans, are critical for diagnosing and evaluating various medical conditions. These imaging techniques provide valuable insights into the body's internal structures, aiding in the detection of abnormalities, assessment of disease progression, and development of treatment strategies. This article delves into two primary radiological investigations, chest X-rays and CT scans, outlining their purpose, procedures, and...
733
Imaging Studies II: Positron Emission Tomography and Scintigraphy01:25

Imaging Studies II: Positron Emission Tomography and Scintigraphy

Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
318
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
126