Related Experiment Video
Updated: Nov 15, 2025

Nasal Brushing Sampling and Processing Using Digital High Speed Ciliary Videomicroscopy – Adaptation for the COVID-19 Pandemic
Published on: November 7, 2020
M-BLUE protocol for coronavirus disease-19 (COVID-19) patients: interobserver variability and correlation with
1Department of Ultrasound, Peking University Third Hospital, Beijing, 1000191, China.
Aim:
To retrospectively evaluate the interobserver variability of intensive care unit (ICU) practitioners and radiologists who used the M-BLUE (modified bedside lung ultrasound in emergency) protocol to assess coronavirus disease-19 (COVID-19) patients, and to determine the correlation between total M-BLUE protocol score and three different scoring systems reflecting disease severity.
Materials And Methods:
Institutional review board approval was obtained and informed consent was not required. Ninety-six lung ultrasonography (LUS) examinations were performed using the M-BLUE protocol in 79 consecutive COVID-19 patients. Two ICU practitioners and three radiologists reviewed video clips of the LUS of eight different regions in each lung retrospectively. Each observer, who was blind to the patient information, described each clip with M-BLUE terminology and assigned a corresponding score. Interobserver variability was assessed using intraclass correlation coefficient. Spearman's correlation coefficient analysis (R-value) was used to assess the correlation between the total score of the eight video clips and disease severity.
Results:
For different LUS signs, fair to good agreement was obtained (ICC = 0.601, 0.339, 0.334, and 0.557 for 0-3 points respectively). The overall interobserver variability was good for both the five different readers and consensus opinions (ICC = 0.618 and 0.607, respectively). There were good correlations between total LUS score and scores from three systems reflecting disease severity (R=0.394-0.660, p<0.01).
Conclusion:
In conclusion, interobserver agreement for different signs and total scores in LUS is good and justifies its use in patients with COVID-19. The total scores of LUS are useful to indicate disease severity.
More Related Videos
05:58Evaluation of a Point-of-Care Testing Analyzer for Measuring Peripheral Blood Leukocytes
Published on: March 22, 2022
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024