Safe procedures despite ultra low radiation doses during catheter ablations of atrial and ventricular arrhythmias-A
Philipp Attanasio1,2, Martin Huemer1,2, Nora Kaehler1,2
1Department of Cardiology, Charité-Universitätsmedizin Berlin, Campus Benjamin Franklin, Berlin, Germany.
Introduction:
Despite the development of non-fluoroscopic catheter visualization options, fluoroscopy is still used in most ablation procedures. The aim of this multicenter study was to evaluate the safety and efficacy of a new ultra-low dose radiation protocol for EP procedures in a large number of patients.
Methods And Results:
A total of 3462 consecutive patients (male 1926 (55.6%), age 64.4 ± 14.0 years, BMI 26.65 ± 4.70) undergoing radiofrequency ablation (left atrial (n = 2316 [66.9%], right atrial (n = 675 [19.5%], or ventricular (n = 471 [13.6%]) in three German centers were included in the analysis. Procedures were performed using a new ultra-low dose protocol operating at 8nGy for fluoroscopy and 36nGy for cine-loops. Additionally a very low framerate (2-3FPS) was used. Using the new protocol very low Air kerma-area product (KAP) values were achieved for left atrial ablations (104.25 ± 84.22 μGym2 ), right atrial ablations (70.98 ± 94.79 μGym2 ) and ablations for ventricular tachycardias or PVCs (78.62 ± 66.59 μGym2 ). Acute procedural success was achieved in 3289/3388 (97.1%) while the rate of major complications was very low compared to previously published studies not using low dose settings (n = 20, 0.6%).
Conclusion:
The ultra-low dose, low framerate protocol leads to very low radiation doses for all EP procedures while neither procedural time, fluoroscopy time nor success or complication rates were compromised. When compared to current real-world Air KAP data the new ultra-low dose fluoroscopy protocol reduces radiation exposure by more than 90%.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
04:58Reduced Procedure Time and Variability with Active Esophageal Cooling During Radiofrequency Ablation for Atrial Fibrillation
Published on: August 25, 2022
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization IV: Nursing Management
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Cardiac Catheterization III: Left Heart Catheterization
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...