Related Experiment Video
Updated: Nov 15, 2025

An In Vitro Approach to Photodynamic Therapy
Published on: August 17, 2018
Validation of an apoptosis assay for extracorporeal photopheresis
Viola Hähnel1, Frauke Dormann1, Katharina Kronenberg2
1Institute for Clinical Chemistry and Laboratory Medicine, Transfusion Medicine, University Hospital Regensburg, Regensburg, Germany.
Objectives:
This validation study investigated a flow cytometric apoptosis assay according to good manufacturing practice (GMP).
Background:
Extracorporeal photopheresis (ECP) is a treatment for various immunological diseases and cutaneous T-cell lymphomas. It is based on the induction of apoptosis by 8-methoxypsoralene and ultraviolet A light. The quantification of apoptosis is therefore essential for ECP improvements. However, despite numerous publications on apoptosis, validated technical details are lacking.
Methods And Materials:
Mononuclear cells were collected by apheresis and treated by ECP or camptothecin. Samples taken before and after ECP were cultured for 24, 48 and 72 h and analysed for apoptosis and viability of T cells and monocytes by flow cytometry with Annexin V and 7-AAD staining. Accuracy of the assay, intra- and inter-assay precision and the pre-analytical and analytical stability of the analytes were the investigated parameters.
Results:
Our data indicate that the median intra- and inter-assay precision coefficient of variation for T cells was 3.86% and 4.80%, respectively. Pre-analytical stability of T cells and monocytes was ensured during short-term storage for up to 2 h on ice. After staining, analytical stability was limited to 30 min, likely because of ongoing apoptosis and loss of monocytes due to plastic adhesion.
Conclusion:
The results of this validation study show that the assay is GMP-compliant and that its reliability, accuracy and precision are acceptable. While pre-analytical stability of the cells was compatible with on-site procedures, our analytical stability data indicate that this assay is not suited for batch mode analysis of ECP products.