Measurement of Spatial Stability in Precision Grip
Published on: June 4, 2020
Agreement Between the Iron Path App and a Linear Position Transducer for Measuring Average Concentric Velocity and
Jovana Kasovic1, Benjamin Martin1, Joseph P Carzoli2
1Department of Exercise Science, Lindenwood University Belleville, Belleville Illinois.
Abstract:
Kasovic, J, Martin, B, Carzoli, JP, Zourdos, MC, and Fahs, CA. Agreement between the Iron Path app and a linear position transducer for measuring average concentric velocity and range of motion of barbell exercises. J Strength Cond Res 35(2S): S95-S101, 2021-The purpose of this study was to compare average concentric velocity (ACV) and range of motion (ROM) values measured by the Iron Path (IP) app to the previously validated Open Barbell System (OBS) linear position transducer during the front and back squat and conventional and sumo deadlift. Twenty-seven men and women (21 ± 3 years old; 76.7 ± 14.5 kg; 1.72 ± 0.09 m) with squat and deadlift training experience completed a modified one repetition maximum protocol on 4 separate occasions in a randomized order. The IP app and OBS device recorded ACV and ROM during each protocol. The level of statistical significant was set at p ≤ 0.05. Bland-Altman plots showed fairly large limits of agreement for both ACV and ROM. Furthermore, 95% confidence intervals for the intraclass correlation coefficients indicated the agreement in ACV between the devices for each of the 4 lifts to range from 0.648-0.876 to 0.849-0.930 and for agreement in ROM between devices to range from -0.053-0.480 to 0.545-0.770. Compared with the OBS, the IP app recorded significantly (p < 0.05) lower ACV values for the front squat and back squat and greater ROM values for the sumo deadlift. We suggest the IP app should not be used in place of a validated linear position transducer for measuring ACV or ROM for barbell lifts.
More Related Videos
Related Concept Videos
Relative Motion Analysis - Velocity
When an external force is exerted, it sets the crank into a rotational movement. This, in turn, instigates the motion of the connecting rod, leading to what is referred to as a general plane motion. This process involves two key points - point A on the connecting rod...
Relative Motion Analysis - Acceleration
Relating Angular And Linear Quantities - I
When comparing the linear and rotational variables individually, the linear variable of position has physical units of meters, whereas the angular position variable has dimensionless units of radians, as it is the ratio of two lengths. The linear velocity...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Relating Angular And Linear Quantities - II
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...