Related Experiment Video
Updated: Nov 15, 2025

Systematic Hearing Performance Evaluation Process for Adolescents with Cochlear Implantation at Early Ages
Published on: March 24, 2023
Evaluation of Italian Simplified Matrix Test for Speech-Recognition Measurements in Noise
Giuseppina Emma Puglisi1, Federica di Berardino2,3, Carla Montuschi4
1Department of Energy, Politecnico di Torino, 10124 Torino, Italy.
Abstract:
This study aimed at the evaluation of a simplified Italian matrix test (SiIMax) for speech-recognition measurements in noise for adults and children. Speech-recognition measurements with adults and children were conducted to examine the training effect and to establish reference speech-recognition thresholds of 50% (SRT50) and 80% (SRT80) correct responses. Test-list equivalency was evaluated only with adults. Twenty adults and 96 children-aged between 5 and 10 years-participated. Evaluation measurements with the adults confirmed the equivalence of the test lists, with a mean SRT50 of -8.0 dB and a standard deviation of 0.2 dB across the test lists. The test-specific slope (the average of the list-specific slopes) was 11.3%/dB, with a standard deviation of 0.6%/dB. For both adults and children, only one test list of 14 phrases needs to be presented to account for the training effect. For the adults, adaptive measurements of the SRT50 and SRT80 showed mean values of -7.0 ± 0.6 and -4.5 ± 1.1 dB, respectively. For children, a slight influence of age on the SRT was observed. The mean SRT50s were -5.6 ± 1.2, -5.8 ± 1.2 and -6.6 ± 1.3 dB for the children aged 5-6, 7-8 and 9-10 years, respectively. The corresponding SRT80s were -1.5 ± 2.7, -3.0 ± 1.7 and -3.7 ± 1.4 dB. High test-retest reliabilities of 1.0 and 1.1 dB for the SRT80 were obtained for the adults and children, respectively. This makes the test suitable for accurate and reliable speech-recognition measurements.
Related Concept Videos
Expected Frequencies in Goodness-of-Fit Tests
Root Mean Square
For example, consider the velocity of gas molecules in a container. The gas molecules are moving in different directions, which might impart positive and negative...
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Bonferroni Test
The means of different samples are first paired in all possible combinations.
The null hypothesis of the...
Classification of Signals
A continuous-time signal holds a value at every instant in time, representing information seamlessly. In contrast, a discrete-time signal holds values only at specific moments, often denoted as x(n), where...
Goodness-of-Fit Test

