The Effect of Ventilation with Individualized Positive End-Expiratory Pressure on Postoperative Atelectasis in
Hyun-Kyu Yoon1, Bo Rim Kim1, Susie Yoon1
1Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, #101 Daehak-ro, Jongno-gu, Seoul 03080, Korea.
Abstract:
For patients undergoing robot-assisted radical prostatectomy, the pneumoperitoneum with a steep Trendelenburg position could worsen intraoperative respiratory mechanics and result in postoperative atelectasis. We investigated the effects of individualized positive end-expiratory pressure (PEEP) on postoperative atelectasis, evaluated using lung ultrasonography. Sixty patients undergoing robot-assisted radical prostatectomy were randomly allocated into two groups. Individualized groups (n = 30) received individualized PEEP determined by a decremental PEEP trial using 20 to 7 cm H2O, aiming at maximizing respiratory compliance, whereas standardized groups (n = 30) received a standardized PEEP of 7 cm H2O during the pneumoperitoneum. Ultrasound examination was performed on 12 sections of thorax, and the lung ultrasound score was measured as 0-3 by considering the number of B lines and the degree of subpleural consolidation. The primary outcome was the difference between the lung ultrasound scores measured before anesthesia induction and just after extubation in the operating room. An increase in the difference means the development of atelectasis. The optimal PEEP in the individualized group was determined as the median (interquartile range) 14 (12-18) cm H2O. Compared with the standardized group, the difference in the lung ultrasound scores was significantly smaller in the individualized group (-0.5 ± 2.7 vs. 6.0 ± 2.9, mean difference -6.53, 95% confidence interval (-8.00 to -5.07), p < 0.001), which means that individualized PEEP was effective to reduce atelectasis. The lung ultrasound score measured after surgery was significantly lower in the individualized group than the standardized group (8.1 ± 5.7 vs. 12.2 ± 4.2, mean difference -4.13, 95% confidence interval (-6.74 to -1.53), p = 0.002). However, the arterial partial pressure of the oxygen/fraction of inspired oxygen levels during the surgery showed no significant time-group interaction between the two groups in repeated-measures analysis of variance (p = 0.145). The incidence of a composite of postoperative respiratory complications was comparable between the two groups. Individualized PEEP determined by maximal respiratory compliance during the pneumoperitoneum and steep Trendelenburg position significantly reduced postoperative atelectasis, as evaluated using lung ultrasonography. However, the clinical significance of this finding should be evaluated by a larger clinical trial.
More Related Videos
05:39Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
04:57Prone Lateral Minimally Invasive Retropleural Corpectomy Using a Rotatable Radiolucent Jackson Table
Published on: July 3, 2025
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation I: Indication and Settings
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...