Related Experiment Video
Updated: Nov 15, 2025

A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
Initial Experience with 64Cu-DOTATATE Digital PET of Patients with Neuroendocrine Neoplasms: Comparison with Analog
Mathias Loft1,2, Camilla B Johnbeck1,2, Esben A Carlsen1,2
1Department of Clinical Physiology, Nuclear Medicine & PET and Cluster for Molecular Imaging, Department of Biomedical Sciences, Rigshospitalet and University of Copenhagen, DK-2100 Copenhagen, Denmark.
Abstract:
The recent introduction of solid-state detectors in clinical positron emission tomography (PET) scanners has significantly improved image quality and spatial resolution and shortened acquisition time compared to conventional analog PET scanners. In an initial evaluation of the performance of our newly acquired Siemens Biograph Vision 600 PET/CT (digital PET/CT) scanner for 64Cu-DOTATATE imaging, we compared PET/CT acquisitions from patients with neuroendocrine neoplasms (NENs) grades 1 and 2 and stable disease on CT who were scanned on both our Siemens Biograph 128 mCT PET/CT (analog PET/CT) and digital PET/CT within 6 months as part of their routine clinical management. Five patients fulfilled the criteria and were included in the analysis. The digital PET acquisition time was less than 1/3 of the analog PET acquisition time (digital PET, mean (min:s): 08:20 (range, 07:59-09:45); analog PET, 25:28 (24:39-28:44), p < 0.001). All 44 lesions detected on the analog PET with corresponding structural correlates on the CT were also found on the digital PET performed 137 (107-176) days later. Our initial findings suggest that digital 64Cu-DOTATATE PET can successfully be performed in patients with NENs using an image acquisition time of only 1/3 of what is used for an analog 64Cu-DOTATATE PET.
More Related Videos
10:47Harnessing the Bioorthogonal Inverse Electron Demand Diels-Alder Cycloaddition for Pretargeted PET Imaging
Published on: February 3, 2015
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...