Related Experiment Video
Updated: Nov 15, 2025

Isothermal Titration Calorimetry for Measuring Macromolecule-Ligand Affinity
Published on: September 7, 2011
A Source of Systematic Errors in the Determination of Critical Micelle Concentration and Micellization Enthalpy by
Mónica Corea1, Rogelio Jiménez-Juárez2, Gabriela Martínez-Mejía2
1Programa de Nanociencias y Micro-Nanotecnologías, Instituto Politécnico Nacional, Escuela Superior de Ingeniería e Industrias Extractivas, UPALM, Edificio Z-5 PB, San Pedro Zacatenco, Del. Gustavo A. Madero, C.P. 07738 Ciudad de Mexico, Mexico.
Abstract:
Isothermal titration calorimetry is frequently employed to determine the critical micelle concentration and the micellization enthalpy of surfactants in terms of geometrical characteristics of the titration curves. Previously we have shown theoretically that even for an infinitesimal injection, the heat per titrant mol depends on the stock solution concentration. In this work, we explore experimentally the influence of the stock solution concentration on the geometrical characteristics of the titration curve and its effect in determining the critical micelle concentration and the micellization enthalpy of surfactants. The systematic study of this phenomenology involves a great number of measurements at different temperatures with several repetitions carried out using a robotic calorimeter. As surfactant hexadecyltrimethylamonium bromide was used. The magnitude and shape of the heat titration depend on the stock solution concentration. As a consequence, the inflexion-point, break-point, and step-height decrease until a limiting value. A qualitative analysis suggests that the limiting value depends only on substance. This work shows that graphical methods could not be suitable for the calculation of the critical micelle concentration and micellization enthalpy because the magnitude and shape of the titration curve depend on the stock solution concentration. Micellar properties should be calculated by the application of theoretical models as in the ligand-binding studies.
Related Concept Videos
Constant Pressure Calorimetry
Enthalpy of Solution
Calorimetry
Chemical Equilibria: Systematic Approach to Equilibrium Calculations
The first step is to identify all the chemical reactions involved, The...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Constant Volume Calorimetry

