Related Experiment Video
Updated: Nov 15, 2025

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Static and Dynamic Performances of Chopped Carbon-Fiber-Reinforced Mortar and Concrete Incorporated with Disparate
Yeou-Fong Li1, Kun-Fang Lee1, Gobinathan Kadagathur Ramanathan1
1Department of Civil Engineering, National Taipei University of Technology, 1, Sec. 3, Chung-Hsiao E. Rd., Taipei 10608, Taiwan.
Abstract:
The impact load, such as seismic and shock wave, sometimes causes severe damage to the reinforced concrete structures. This study utilized different lengths of chopped carbon fibers to develop a carbon-fiber-reinforced mortar (CFRM) and carbon-fiber-reinforced concrete (CFRC) with high impact and anti-shockwave resistance. The different lengths (6, 12, and 24 mm) of chopped carbon fibers were pneumatically dispersed and uniformly mixed into the cement with a 1% weight proportion. Then the CFRM and CFRC specimens were made for static and dynamic tests. The compressive and flexural strengths of the specimens were determined by using the standard ASTM C39/C 39M and ASTM C 293-02, respectively. Meanwhile, a free-fall impact test was done according to ACI 544.2R-89, which was used to test the impact resistances of the specimens under different impact energies. The CFRM and CFRC with a length of 6 mm exhibit maximum compressive strength. Both flexural and free-fall impact test results show that the 24 mm CFRM and CFRC enhances their maximum flexural strength and impact numbers more than the other lengths of CFRM, CFRC, and the benchmark specimens. After impact tests, the failure specimens were observed in a high-resolution optical microscope, to identify whether the failure mode is slippage or rupture of the carbon fiber. Finally, a blast wave explosion test was conducted to verify that the blast wave resistance of the 24 mm CFRC specimen was better than the 12 mm CFRC and benchmark specimens.
More Related Videos
09:54Author Spotlight: Enhancing Fiber Composite Laminate Quality with the Wet Hand Lay-Up/Vacuum Bag Process
Published on: June 30, 2023
05:38Production and Analysis of Sporosarcina pasteurii Biocement Bricks Using Custom 3D-Printed Molds for Unconfined Compression Tests
Published on: March 7, 2025
Related Concept Videos
Fiber Reinforced Concrete
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Fatigue Strength of Concrete
Mortar Properties
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...