Observer Influence with Other Variables on the Accuracy of Ultrasound Estimation of Fetal Weight at Term

Mariola Sánchez-Fernández1, Maria E Corral1, Longinos Aceituno1

  • 1Obstetrics and Gynecology Service, La Inmaculada Hospital, Huércal-Overa, 04600 Almería, Spain.

Background and Objectives: The accuracy with which the estimation of fetal weight (EFW) at term is determined is useful in order to address obstetric complications, since it is a parameter that represents an important prognostic factor for perinatal and maternal morbidity and mortality. The aim of this study was to determine the role of the experienced observers with other variables that could influence the accuracy of the ultrasound used to calculate EFW at term, carried out within a period of seven days prior to delivery, in order to assess interobserver variability. Materials and Methods: A cross-sectional study was performed including 1144 pregnancies at term. The validity of the ultrasound used to calculate EFW at term was analyzed using simple error, absolute error, percentage error and absolute percentage error, as well as the percentage of predictions with an error less than 10 and 15% in relation to maternal, obstetric and ultrasound variables. Results: Valid predictions with an error less than 10 and 15% were 74.7 and 89.7% respectively, with such precision decreasing according to the observer as well as in extreme fetal weights. The remaining variables were not significant in ultrasound EFW at term. The simple error, absolute error, percentage error and absolute percentage error were greater in cases of extreme fetal weights, with a tendency to overestimate the low weights and underestimate the high weights. Conclusions: The accuracy of EFW with ultrasound carried out within seven days prior to birth is not affected by maternal or obstetric variables, or by the time interval between the ultrasound and delivery. However, accuracy was reduced by the observers and in extreme fetal weights.

Related Concept Videos

Regression Toward the Mean01:52

Regression Toward the Mean

Regression toward the mean (“RTM”) is a phenomenon in which extremely high or low values—for example, and individual’s blood pressure at a particular moment—appear closer to a group’s average upon remeasuring. Although this statistical peculiarity is the result of random error and chance, it has been problematic across various medical, scientific, financial and psychological applications. In particular, RTM, if not taken into account, can interfere when...
6.6K
Uncertainty in Measurement: Accuracy and Precision03:37

Uncertainty in Measurement: Accuracy and Precision

Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value. 
98.1K
Errors occurring during blood pressure monitoring01:25

Errors occurring during blood pressure monitoring

Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
1.1K
Ultrasonography01:17

Ultrasonography

Ultrasonography is an imaging technique that uses high-frequency sound waves to visualize the body's internal structures. It is a non-invasive and safe procedure that does not involve the use of ionizing radiation, making it widely used in various medical fields. Ultrasonography is used to study heart function, blood flow in the neck or extremities, certain conditions such as gallbladder disease, and fetal growth and development.
During an ultrasonography procedure, a handheld device called...
7.0K