Related Experiment Video
Updated: Nov 15, 2025

Candidate Gene Testing in Clinical Cohort Studies with Multiplexed Genotyping and Mass Spectrometry
Published on: June 21, 2018
Application of a probabilistic genotyping software to MPS mixture STR data is supported by similar trends in LRs
Corina C G Benschop1, Kristiaan J van der Gaag1, Jennifer de Vreede1
1Division of Biological Traces, Netherlands Forensic Institute, The Hague, The Netherlands.
Abstract:
The interpretation of short tandem repeat (STR) profiles can be challenging when, for example, alleles are masked due to allele sharing among contributors and/or when they are subject to drop-out, for instance from sample degradation. Mixture interpretation can be improved by increasing the number of STRs and/or loci with a higher discriminatory power. Both capillary electrophoresis (CE, 6-dye) and massively parallel sequencing (MPS) provide a platform for analysing relatively large numbers of autosomal STRs. In addition, MPS enables distinguishing between sequence variants, resulting in enlarged discriminatory power. Also, MPS allows for small amplicon sizes for all loci as spacing is not an issue, which is beneficial with degraded DNA. Altogether, MPS has the potential to increase the weights of evidence for true contributors to (complex) DNA profiles. In this study, likelihood ratio (LR) calculations were performed using STR profiles obtained with two different MPS systems and analysed using different settings: 1) MPS PowerSeq™ Auto System profiles analysed using FDSTools equipped with optimized settings such as noise correction, 2) ForenSeq™ DNA Signature Prep Kit profiles analysed using the default settings in the Universal Analysis Software (UAS), and 3) ForenSeq™ DNA Signature Prep Kit profiles analysed using FDSTools empirically adapted to cope with one-directional reads and provisional, basic settings. The LR calculations used genotyping data for two- to four-person mixtures varying for mixture proportion, level of drop-out and allele sharing and were generated with the continuous model EuroForMix. The LR results for the over 2000 sets of propositions were affected by the variation for the number of markers and analysis settings used in the three approaches. Nevertheless, trends for true and non-contributors, effects of replicates, assigned number of contributors, and model validation results were comparable for the three MPS approaches and alike the trends known for CE data. Based on this analogy, we regard the probabilistic interpretation of MPS STR data fit for forensic DNA casework. In addition, guidelines were derived on when to apply LR calculations to MPS autosomal STR data and report the corresponding results.
More Related Videos
10:33Multi-locus Variable-number Tandem-repeat Analysis of the Fish-pathogenic Bacterium Yersinia ruckeri by Multiplex PCR and Capillary Electrophoresis
Published on: June 17, 2019
10:27Methods to Increase the Sensitivity of High Resolution Melting Single Nucleotide Polymorphism Genotyping in Malaria
Published on: November 10, 2015