Related Experiment Video
Updated: Oct 1, 2026

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
An elephant trunk stent graft strayed into the false lumen leading to a death during the Sun's operation: A case
Fushuo Zhou1, Hong Chai2, Ruisheng Liu3
1Department of Cardiovascular Surgery, First Hospital of Lanzhou University, Lanzhou 730030. zfsxnu@126.com.
Abstract:
Type A aortic dissection (AD) is a critical and severe disease with high mortality. The Sun's operation is a standard surgical method for this kind of disease at present. For the procedure, an elephant trunk stent is inserted into the true lumen of the descending aorta and the aortic arch is replaced. A patient was admitted to the First Hospital of Lanzhou University due to sudden chest and back pain for 6 days. Computed tomography angiography (CTA) showed type A AD. Ascending aorta replacement, Sun's operation, and ascending aorta to right femoral artery bypass grafting were performed. After surgery, the patient's condition was worsened. The digital subtraction angiography (DSA) showed the elephant trunk stent was inserted into the false lumen of AD, leading to the occlusion of the large blood vessel at the distal part of the abdominal aorta and below. Although we performed intima puncture and endovascular aortic repair, the patient was still dead.