Comparison between Branded and Generic Furosemide 40 mg Tablets Using Thermal Gravimetric Analysis and Fourier

Mosab Arafat1, Khairi M Fahelelbom1, Muhammad K Sarfraz1

  • 1College of Pharmacy, Al Ain University, Al Ain, Abu Dhabi, UAE.

Abstract

Related Concept Videos

Pharmaceutical Alternatives: Stability-Related Therapeutic Nonequivalence01:22

Pharmaceutical Alternatives: Stability-Related Therapeutic Nonequivalence

Generic intravenous (IV) drugs are considered bioequivalent to their branded counterparts due to their 100% bioavailability upon administration. However, variations in stability among different drug products can significantly influence their therapeutic performance, even if they are pharmaceutically equivalent.Cefuroxime, a prophylactic antimicrobial, is often used as a single-dose IV injection for patients undergoing coronary artery bypass grafting surgery. A 3 g dose typically provides...
73
Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules01:18

Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules

Bioequivalence in generic drugs, such as tablets and capsules, refers to their pharmaceutical equivalence to the brand-name counterparts. However, for therapeutic equivalence, manufacturers must also consider physical attributes like size, shape, and weight (FDA Guidance for Industry, December 2003). Discrepancies in these aspects could impact patient compliance and cause medication errors. For instance, swallowing difficulties, often experienced with larger tablets or capsules, can lead to...
60
Drug Dissolution: Requirements and Profile Comparison01:14

Drug Dissolution: Requirements and Profile Comparison

The acceptance criteria for dissolution profile data are anchored in Q values, representing the percentage of drug dissolved within a specified period. This assessment unfolds in three stages:First Stage: The test passes if all six drug dosage units are equal to or greater than Q plus 5%; otherwise, the sample proceeds to the second stage.Second Stage: The average of twelve units must be equal to or greater than Q, with no unit falling below Q - 15% to pass; if not, it progresses to the final...
109
IR Spectrometers01:25

IR Spectrometers

There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
1.7K
Bioequivalence studies: Biowaivers01:13

Bioequivalence studies: Biowaivers

Body:In certain scenarios, in vitro dissolution tests can replace in vivo bioequivalence studies. This is particularly true when a drug product, though available in varying strengths, maintains proportional similarity in its active and inactive ingredients. In such cases, the need for in vivo bioequivalence studies for lower strength variants may be waived, provided dissolution tests and in vivo studies on the highest strength yield satisfactory results.Bioequivalence can be indicated through...
74
IR Frequency Region: Fingerprint Region01:03

IR Frequency Region: Fingerprint Region

IR spectra are divided into two main regions: the diagnostic region and the fingerprint region. The diagnostic region of the spectrum lies above 1500 cm−1. The absorptions resulting from single-bond vibrations of the N–H, C–H, and O–H stretch at higher wavenumbers and appear on the left side of the spectrum. The stretching absorptions of the C≡C and C≡N occur between 2100–2300 cm−1. In contrast, those arising from stretching absorptions of the...
1.5K