Utilization and reproducibility of World Endoscopy Organization post-colonoscopy colorectal cancer algorithms:
David Beaton1, Iosif Beintaris1, Matthew D Rutter1,2
1Gastroenterology, University Hospital of North Tees, Stockton on Tees, United Kingdom.
Background:
Colorectal cancer (CRC) diagnosed following a cancer-negative colonoscopy is termed post-colonoscopy CRC (PCCRC). In addition to calculating PCCRC rates, the World Endoscopy Organization (WEO) recommends review of individual PCCRC cases, including categorization into interval/non-interval PCCRCs, and root cause analysis to determine the most plausible explanation. We aimed to test the usability, reproducibility, and outcomes of the WEO algorithms.
Methods:
All CRC cases diagnosed from January 2015 to December 2016 in a single organization were cross referenced with local endoscopy and pathology databases to identify cases of PCCRC. We assessed: 1) WEO most plausible explanation for PCCRC; and 2) WEO PCCRC interval/non-interval subtype categorization. Interobserver agreement was measured using Cohen's kappa (κ). Cases with interobserver variation underwent panel discussion to reach consensus.
Results:
Among 527 patients with CRC, 48 PCCRCs were identified. A consistent most plausible explanation was found in 97 % of cases, showing almost perfect agreement (κ = 0.94). Most PCCRCs (66 %) were attributed to "possible missed lesion, prior examination adequate." Interval/non-interval categorization was consistent in 77 %, showing substantial agreement (κ = 0.67). Following panel discussion, consensus was reached in all cases. Overall, 15 % were categorized as interval and 85 % as non-interval PCCRCs (12 % type A, 31 % type B, and 42 % type C).
Conclusions:
Review of PCCRC cases using WEO recommendations was performed accurately at a local level using readily available clinical information. The high number of non-interval type B PCCRCs suggests a significant proportion of PCCRCs could be avoided by better adherence to recommended surveillance intervals.
More Related Videos
15:49Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
06:28E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
Related Concept Videos
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Procedures III: Video Capsule Endoscopy