Comparison of VerifyNow, thromboelastography, and PL-12 in patients with minor ischemic stroke or transient ischemic
Lin Ma1,2,3, Weiqi Chen1,2,3, Yuesong Pan1,2,3
1Department of Neurology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
High on-treatment platelet reactivity (HOPR) is associated with stroke recurrence. It is important to find a reliable method to assess HOPR. We aimed to compare the correlations between VerifyNow™ system, thromboelastography (TEG), and Aggrestar platelet function analyzer (PL-12) on platelet activity in patients with minor ischemic stroke or transient ischemic attack (TIA) after dual antiplatelet therapy for 7 days. About 276 patients were included. Spearman's correlation coefficient and the kappa coefficient were adopted to evaluate associations among the three test methods. An obvious correlation between VerifyNow and TEG on HOPR-ADP (r=0.64, p<0.001) was found. The correlations of HOPR-ADP between PL-12 and the other two platelet function analyzers were moderate (PL-12 versus VerifyNow, r=0.47, p<0.001; PL-12 versus TEG, r=0.25, p<0.001). The correlations of HOPR-AA were limited among these three platelet function analyzers (VerifyNow versus TEG, r=0.09, p=0.14; VerifyNow versus PL-12, r=0.15, p=0.01; PL-12 versus TEG, r=0.10, p=0.09). Correlations among different platelet function analyzers were varied. VerifyNow and TEG were more correlative than PL-12 on HOPR-ADP. The consistence of HOPR-AA was limited among VerifyNow, TEG and PL-12. The proportion of stroke recurrence and composite events in patients with HOPR-ADP assessing by PL-12 was higher than VerifyNow and TEG.
High on-treatment platelet reactivity (HOPR) is associated with stroke recurrence. It is important to find a reliable method to assess HOPR. We aimed to compare the correlations between VerifyNow™ system, thromboelastography (TEG), and Aggrestar platelet function analyzer (PL-12) on platelet activity in patients with minor ischemic stroke or transient ischemic attack (TIA) after dual antiplatelet therapy for 7 days. About 276 patients were included. Spearman's correlation coefficient and the kappa coefficient were adopted to evaluate associations among the three test methods. An obvious correlation between VerifyNow and TEG on HOPR-ADP (r=0.64, p<0.001) was found. The correlations of HOPR-ADP between PL-12 and the other two platelet function analyzers were moderate (PL-12 versus VerifyNow, r=0.47, p<0.001; PL-12 versus TEG, r=0.25, p<0.001). The correlations of HOPR-AA were limited among these three platelet function analyzers (VerifyNow versus TEG, r=0.09, p=0.14; VerifyNow versus PL-12, r=0.15, p=0.01; PL-12 versus TEG, r=0.10, p=0.09). Correlations among different platelet function analyzers were varied. VerifyNow and TEG were more correlative than PL-12 on HOPR-ADP. The consistence of HOPR-AA was limited among VerifyNow, TEG and PL-12. The proportion of stroke recurrence and composite events in patients with HOPR-ADP assessing by PL-12 was higher than VerifyNow and TEG.
More Related Videos
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Venous Thrombosis III: Interprofessional Care
Acute Coronary Syndrome III: Diagnostic Studies